气相色谱法同时测定尿中N-甲…

气相色谱法同时测定尿中N-甲基甲酰胺和N-甲基乙酰胺的含量PEG-20M
产品简介
详细介绍
  • 参考报价:电议 产地:山东 品牌:浩瀚色谱 型号:PEG-20M 更新时间:2026/2/10

气相色谱法同时测定尿中N-甲基甲酰胺和N-甲基乙酰胺的含量PEG-20M

气相色谱法同时测定尿中N-甲基甲酰胺和N-甲基乙酰胺的含量PEG-20M 详细信息:


名称:毛细管柱
固定相:聚乙二醇
规格:30m*0.53mm*1.0um
型号:PEG-20M
应用:GBZ∕T 312-2018 尿中N-甲基乙酰胺测定 气相色谱法


浩瀚色谱(山东)应用技术开发有限公司建立同时测定N,N-二甲基甲酰胺(DMF)和N,N-二甲基乙酰胺(DMAC)职业接触者尿中代谢物N-甲基甲酰胺(NMF)和N-甲基乙酰胺(NMAC)含量的气相色谱方法.方法:将冷冻的尿样离心分离、沉淀杂质后经PEG-20M毛细管色谱柱程序升温分离,尿液中的NMF和NMAC用氮磷检CE器JIAN测,以保留时间定性,峰面积定量.结果:尿中NMF和NMAC在0.4 mg/L~200 mg/L浓度范围内线性关系良好,相关系数均≥0.9999,检出限分别为0.1 mg/L和0.05 mg/L.NMF和NMAC的低中高三个浓度的回收率分别为102%、99%、0%和95%、98%、99%.结论:本法前处理简便,灵敏度和准确性高,是JIAN测DMF和DMAC同时接触人群尿样中NMF和NMAC的好方法.


气相色谱法同时测定尿中N-甲基甲酰胺和N-甲基乙酰胺的含量PEG-20M 测试谱图:



Simultaneous determination of N-methylformamide and N-methylacetamide in urine by gas chromatography PEG-20M


Simultaneous determination of N-methylformamide and N-methylacetamide in urine by gas chromatography PEG-20M Details:




Name: capillary column

Stationary Phase: Polyethylene Glycol

Specifications: 30m*0.53mm*1.0um

Model: PEG-20M

Application: GBZ∕T 312-2018 Determination of N-Methylacetamide in Urine Gas Chromatography



Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. established the simultaneous determination of N,N-dimethylformamide (DMF) and N,N-dimethylacetamide (DMAC) metabolites in the urine of occupational contacts of N-methylmethane Gas chromatographic method for the content of amide (NMF) and N-methylacetamide (NMAC). Method: The frozen urine samples were centrifuged, and the impurities were precipitated, and then separated by temperature-programmed separation on a PEG-20M capillary column. NMAC was detected with nitrogen and phosphorus detector JIAN, and the retention time was used for qualitative determination and peak area for quantification. Results: The linear relationship between NMF and NMAC in urine was good in the concentration range of 0.4 mg/L~200 mg/L, and the correlation coefficients were all ≥0.9999. The out-limits were 0.1 mg/L and 0.05 mg/L, respectively. The recoveries of low, medium and high concentrations of NMF and NMAC were 12%, 99%, 10% and 95%, 98%, 99%, respectively. Conclusion: This method With simple pretreatment, high sensitivity and accuracy, it is a good method for JIAN to measure NMF and NMAC in urine samples of people exposed to DMF and DMAC at the same time.



Simultaneous determination of N-methylformamide and N-methylacetamide in urine by gas chromatography PEG-20M test spectrum


单位名称:浩瀚色谱(山东)应用技术开发有限公司
详细地址:滕州市(商务部和技术部);
QQ:1404939462
联系手机:
联系电话:
我要咨询:我要咨询
传真:0632-5667636
Email:1455546473@qq.com