造血细胞体外实验和试剂,In…

造血细胞体外实验和试剂,InVitroAssaysandReagentsforBlood-FormingCells
产品简介
详细介绍
  • 参考报价:电议 产地:美国 品牌:hemogenix 型号:CAMEO 更新时间:2023/4/3

Cell Types:

In Vitro Assays and Reagents for

Blood-Forming Cells

 

 

 

 

AssaysLHcells

 

Click image for larger view

 

CAMEO™-4, CAMEO™-96, HALO®-96 and 384, HemoFLUOR™-96 and HemoLIGHT™-96 provide you with the widest range of cell-based assays to study stem, progenitor and precursor cells of the blood-forming system. In addition, the culture reagents used in CAMEO™-4 and CAMEO™-96 assays are also available as ColonyGro™ Master Mixes. Similarly, the culture reagents used in most HALO®, HemoFLUOR™ and HemoLIGHT™ assays are available as CellExpand™ Master Mixes. At HemoGenix®, we believe that it is important to use the correct assay for the goal of the experiment or study. That is why we have divided our assays into those that detect and measure proliferation and those that detect differentiation. In addition, we now offer three types of proliferation assay depending on the readout or signal detection system, sensitivity and cost.

  • Use CAMEO™-4 assays and ColonyGro™ Master Mixes when you need a colony-forming cell (CFC) assay and the goal is to detect differentiation ability or potential under clonal conditions.
  • Use CAMEO™-96 when you need a colony-forming cell (CFC) assay, but the goal is to detect both proliferation and differentiation under clonal conditions.
  • Use CAMEO™-96 when the goal is to standardize the "classic" colony-forming cell assay.
  • Use CellExpand™ Master Mixes to perform stem and progenitor cell expansion studies that also require high-content screening, genetic analysis of cells, cell signalling studies etc.
  • Use HALO® to measure proliferation ability or potential of lympho-hematopoietic stem and progenitor cells. This is the most advanced assay that incorporates both SEC™ and bioluminomics™ technology. It is the most sensitive of all assays for hematopoietic cells and includes reagents to calibrate and standardize the assay. To perform HALO®, a plate luminometer is required.
  • Use HemoFLUOR™ when a plate luminometer is not available but a fluorescence plate reader is at hand. HemoFLUOR™ assays incorporate SEC Technology.
  • Use HemoLIGHT™ when neither a plate luminometer or fluorescence plate reader is available. HemoLIGHT™ incorporate SEC™ Technology and uses a normal colorimetric/absorbance plate reader, similar to that for the majority of ELISAs.


Please note: CAMEO™-4 or any colony-forming cell assay cannot be used to quantify proliferation. It is correct to assume that proliferation has taken place so that colonies can be formed, but it is not possible to measure proliferation with a CFC assay. See Proliferation and Differentiation. Please use CAMEO™-96, HALO®, HemoFLUOR™ or HemoLIGHT™ to measure proliferation.

 

 

 


The table below shows the populations that can be detected using CAMEO™-4, CAMEO™-96, HALO® HemoFLUOR™ or HemoLIGHT™. Please note that CAMEO™-96 was formerly designated HALO®-96 MeC (methylcellulose).

 

 

 

 

 


ColonyGro™, CAMEO™-4, CAMEO™-96, CellExpand™, HALO®, HemoFLUOR™ and HemoLIGHT™ Reagents and Assays for

Stem, Progenitor and Precursor Cell Populations

CAMEO™-4 / ColonyGro™ CAMEO™-96 HALO® / CellExpand™ HemoFLUOR™ HemoLIGHT™ Growth Factor/Cytokine Cocktail
HPP-SP 1 HPP-SP 1 HPP-SP 1 NA NA IL-3, IL-6, SCF, TPO, Flt3-L
HPP-SP 2 HPP-SP 2 HPP-SP 2 HPP-SP 2 HPP-SP 2 EPO, GM-CSF, IL-2, IL-3, IL-6, IL-7, SCF, TPO, Flt3-L
CFC-GEMM 1 CFC-GEMM 1 CFC-GEMM 1 CFC-GEMM 1 CFC-GEMM 1 EPO, GM-CSF, IL-3, IL-6, SCF, TPO, Flt3-L
CFC-GEMM 2 CFC-GEMM 2 CFC-GEMM 2 NA NA EPO, GM-CSF, IL-3, IL-6, SCF, TPO
CFC-GEMM 3* NA CFC-GEMM 3* NA NA EPO, GM-CSF, G-CSF, IL-3, IL-6, SCF, TPO (MethoCult™ H4435 "Enriched")
CFC-GEM 1 CFC-GEM 1 CFC-GEM 1 CFC-GEM 1 CFC-GEM 1 EPO, GM-CSF, IL-3, IL-6, SCF
CFC-GEM 2 CFC-GEM 2 CFC-GEM 2 CFC-GEM 2 CFC-GEM 2 EPO, GM-CSF, IL-3, SCF (MethoCult® H4434 "Classic")
CFC-GEM 3* NA CFC-GEM 3* NA NA EPO, GM-CSF, G-CSF, IL-3, SCF (MethoCult™ H4034 "Optimum")
BFU-E 1 BFU-E 1 BFU-E 1 BFU-E 1 BFU-E 1 EPO, IL-3, SCF
BFU-E 2 BFU-E 2 BFU-E 2 NA NA EPO (high dose)
CFU-E CFU-E NA NA NA EPO (low dose)
GM-CFC 1 GM-CFC 1 GM-CFC 1 GM-CFC 1 GM-CFC 1 GM-CSF, IL-3, SCF (MethoCult® H4534 "Classic")
GM-CFC 2* NA GM-CFC 2* NA NA GM-CSF, G-CSF, IL-3, SCF (MethoCult® H4035 "Optimum")
GM-CFC 3 GM-CFC 3 GM-CFC 3 NA NA GM-CSF
G-CFC G-CFC NA NA NA G-CSF
M-CFC M-CFC NA NA NA M-CSF
Mk-CFC 1 Mk-CFC 1 Mk-CFC 1 Mk-CFC 1 Mk-CFC 1 TPO, IL-3, SCF
Mk-CFC 2 Mk-CFC 2 Mk-CFC 2 NA NA TPO
T-CFC T-CFC T-CFC NA NA IL-2
B-CFC B-CFC B-CFC NA NA IL-7

 

NA = not available

* denotes assays and reagents are only available for human cells

 

 

 

 


Assays and Reagents Available for Different Applications

Application Sub-Application Assay
Stem Cells Human, Non-human primate, horse, pig, sheep, dog, rat mouse

CellExpand™ Master Mixes

HALO®-96 Research

HALO®-96 PREP

HemoFLUOR™-96

HemoLIGHT™-96

ColonyGro™ Master Mixes

CAMEO™-4

CAMEO™-96

Research Human, Non-human primate, horse, pig, sheep, dog, rat mouse

CellExpand™ Master Mixes

HALO®-96 Research

HemoFLUOR™-96
HemoLIGHT™-96

ColonyGro™ MAster Mixes

CAMEO™-4

CAMEO™-96

Cellular Therapy Stem cell growth, cell functionality, viability STEMpredict™
CFU/CFC MethoCult® equivalent assays

ColonyGro™ Master Mixes

CAMEO™-4

HALO®-96 PCAEQ

HemoFLUOR™-96 PCAEQ

HemoLIGHT™-PCAEQ

Stem cell quality control assays HALO®-96 SPC-QC
Stem cell potency assays HALO®-96 PQR
Assays for engraftment and reconstitution

HALO®-96 PMT

HemoFLUOR™-96 PMT

HemoLIGHT™-96 PMT

Hemotoxicity Human, Non-human primate, horse, pig, sheep, dog, rat mouse

HALO®-Tox HT,

HALO®-96 PRT

HALO®-384 DDI

Veterinary Science Non-human primate, horse, pig, sheep, dog, rat mouse

CellExpand™ Master Mixes

HALO®-96 Research

HemoFLUOR™-96

HemoLIGHT™-96

ColonyGro™ Master Mixes

CAMEO™-4

CAMEO™-96

 

单位名称:世联博研(北京)科技有限公司
详细地址:北京市海淀区西三旗上奥世纪中心A座9层906
QQ:736597338
联系手机:
联系电话:
我要咨询:我要咨询
传真:010-67529703
Email:slby800@163.com