SUPERDEX7510/300GL

SUPERDEX7510/300GL
产品简介
详细介绍
  • 参考报价:电议 产地:美国 品牌:GE 型号:17-5172-01 更新时间:2017/3/23

 

17-5172-01 SUPEROSE 6 10/300 GL
17-5173-01 SUPEROSE 12 10/300 GL
17-5174-01 SUPERDEX 75 10/300 GL
17-5175-01 SUPERDEX 200 10/300 GL
17-5176-01 SUPERDEX PEPTIDE 10/300 GL
28-9065-61 Superdex 200 5_150 GL
28-9205-04 Superdex 75 5_150 GL
17-0506-01 PP COLUMN MONO Q HR 16/10
17-0507-01 PP COLUMN MONO S HR 16/10
17-1002-01 MONO Q 60/100
17-1177-01 RESOURCE Q, 1 ML
17-1178-01 RESOURCE S, 1 ML
17-1179-01 RESOURCE Q, 6 ML
17-1180-01 RESOURCE S, 6 ML
17-1184-01 RESOURCE ETH 1 ML
17-1185-01 RESOURCE ISO 1 ML
17-1186-01 RESOURCE PHE 1 ML
17-1187-01 RESOURCE HIC TEST KIT
17-5166-01 MONO Q 5/50 GL
17-5167-01 MONO Q 10/100 GL
17-5168-01 MONO S 5/50 GL
17-5169-01 MONO S 10/100 GL
17-5170-01 MONO P 5/50 GL
17-5171-01 MONO P 5/200 GL
17-5177-01 MINI Q 4.6/50 PE
17-5178-01 MINI S 4.6/50 PE
17-5179-01 MONO Q 4.6/100 PE
17-5180-01 MONO S 4.6/100 PE
17-5181-01 SOURCE 15Q 4.6/100 PE
17-5182-01 SOURCE 15S 4.6/100 PE
17-5186-01 SOURCE 15PHE 4.6/100 PE
18-4271-00 O RING 64.5X3 EPDM GLASS TUBE
18-4284-01 FILTER TOOL, 60 MM
18-4610-60 DISTRIBUTION UNIT 60 MM TI 1
18-4610-62 O RING 55X1.6 EPDM

 

 

Superdex™ 75 / Superdex™ 200 Columns

 

  • High-resolution separations of proteins, peptides, and other biomolecules according to size.
  • Ideal for the polishing step in a purification procedure.
  • Separations in two ranges from Mr 3000 up to 600 000 (globular proteins).
  • Easy and predictable scale-up.
  • Excellent reproducibility and durability.
  • For rapid protein homogeneity analysis or purity check use the 5/150 GL short columns

 

Superdex™ 75 / Superdex™ 200 Columns

 

Technical Information

 


Superdex prepacked columns are designed for high-performance, laboratory-scale separations of proteins, peptides, and other biomolecules according to size. High performance gel filtration offers fast separations with high resolution for a variety of applications including protein purification, studies of complex formation, and screening of uncharacterized samples.

 

 

 

Superdex 75 5/150 GL and Superdex 200 5/150 GL have small bed volumes, which is useful for a range of applications such as screening solubilization conditions for membrane proteins, the study of protein-protein interactions, and rapid purity check of proteins. These columns are an excellent choice when time and sample/buffer consumption is more important than the highest resolution since less buffer and sample volumes are required.

 

 

 

Superdex columns 10/300 GL and 5/150 GL are prepacked Tricorn columns, see Tricorn™ Column Family, that provide excellent reproducibility and durability in purification using a chromatography system.

 

 

 

 

TECHNICAL SPECIFICATIONS
Superdex™
Exclusion limit (Mr)
Superdex™ 75 1 × 105 globular protein
Superdex™ 200 1.3 × 106 globular protein
Separation range (Mr)
Superdex™ 75 3000-70 000 globular protein
Superdex™ 200 10 000-600 000 globular protein
Matrix Spherical composite of cross-linked agarose and dextran
Average particle size 13 μm
Chemical stability Stable in all common buffers:
1 M acetic acid, 8 M urea,
6 M guanidine hydrochloride,
30% isopropanol, 70% ethanol,
1 M NaOH (for cleaning in place)
pH stability 3-12 (working and long term), 1-14 (short term)
Storage 20% ethanol
Storage temperature 4°C to 30°C
Superdex™ 10/300 GL Columns (Tricorn)*
Bed dimensions 10 × 300 mm
Recommended sample volume 25-250 μl
Bed volume 24 ml
Max. pressure  
Superdex™ 75 18 bar (261 psi, 1.8 MPa)
Superdex™ 200 15 bar (217 psi, 1.5 MPa)
Max. flow rate (H2O at 25°C)
Superdex™ 75 1.5 ml/min
Superdex™ 200 1.0 ml/min
Theoretical plates > 30 000 m-1
Superdex™ PC 3.2/30 Columns
Bed dimensions 3.2 × 300 mm
Bed volume 2.4 ml
Recommended sample volume 2-25 μl
Max. pressure  
Superdex™ 75 24 bar (348 psi, 2.4 MPa)
Superdex™ 200 12 bar (174 psi, 1.2 MPa)
Max. flow rate (H2O at 25°C)
Superdex™ 75 0.100 ml/min
Superdex™ 200 0.100 ml/min
Theoretical Plates > 30 000 m-1
Superdex™ 5/150 column (Tricorn™)
Bed volume 3 ml
Bed dimensions 5 × 150 mm
Recommended sample volume 4 - 50 μl
Recommended flow rate 0.15 - 0.6 ml/min
Max. pressure  
Superdex 75 1.8 MPa
Superdex 200 1.5 MPa
Max. flow rate (H20 at 25°C)  
Superdex 75 0.7 ml/min
Superdex 200 0.8 ml/min
Theoretical plates > 25000 m-1
* Columns are not suitable for use with ÄKTAprime™ plus system.

 

 

 

 

 

Click here to view this image in high resolution
Separation of standard proteins on Tricorn™ Superdex™ 200.

 

 

 

Click here to view this image in high resolution
Separation of monomer and dimer on Tricorn™ Superdex™ 75.

 

 

 

Click here to view this image in high resolution
Column performance test with a set of standard proteins on Superdex™ 75
5/150 GL.

 

http://www.gelifesciences.com/aptrix/upp01077.nsf/Content/Products?OpenDocument&moduleid=165422

单位名称:上海基星生物科技有限公司
详细地址:上海浦东张江高科技园区科苑路201号B404室
QQ:1013862246
联系手机:
联系电话:
我要咨询:我要咨询
传真:021-50801884
Email:342786402@qq.com
询价热线在线客服QQ咨询