产品介绍
589nm低噪声激光器
LLDZS-589
589nm低噪声激光器,589nm低噪声激光器
Wavelength (nm)波长 | 589± 1 |
Operating mode工作模式 | CW |
Output power (mW)功率 | 200-300 |
Power stability (rms, over 4 hours)功率稳定性 | <3%, <2%, < 1%, <0.5% |
Spectral line width (nm)线宽 | <0. 1, <0.003 |
Transverse mode光斑模式 | TEM00 |
Noise of amplitude (rms, 1Hz~20MHz)性噪比 | < 1%, <0.5% |
M2 factor光束质量 | < 1.2 |
Beam diameter at the aperture ( 1/e2, mm)光斑 | < 1.5 |
Beam divergence, full angle (mrad)发散角 | < 1.5 |
Polarization Ratio偏振比 | > 100:1, Horizontal (Vertical Optional) |
Warm-up time (minutes)上升时间 | <5 |
Pointing stability after warm-up (mrad)光斑指向稳定性 | <0.05 |
Beam height from base plate (mm)中心高 | 27.4 |
Max. Laser Head Base plate Temp (°C)工作温度 | 50 |
Operating Temperature (°C)工作温度 | 10-35 |
Power supply (90-264VAC)供电 | 220V |
Expected lifetime (hours)寿命 | 10000 |
Warranty保修 | 1 year |
570nm激光器
(型号:LL570-200mw)
产品特点:
l 功率稳定、可调节,操作简便;
l 采用原装进口 LD,性能可靠,使用寿命长;
l 电源自带过热、限流保护电路,可外接高速调制;
l 适用于光谱分析、材料分析、生物工程、光电检测、医疗等。
Wavelength (nm)波长 | 570±1 |
Operating mode输出方式 | CW |
Output power (mW)输出功率 | 1-200 |
Power stability (rms, over 4 hours)功率稳定性 | <5%, <3% |
Transverse mode光斑模式 | Near TEM00 |
Beam diameter at the aperture (1/e2, mm)光斑尺寸 | 4
|
Beam divergence (mrad)发散角 | <3 |
Cooled method制冷 | Fan Cooled/ Water Cooled |
Warm-up time (minutes)预热时间 | <10 |
Beam height from base plate (mm)中心高 | 91@Fan Cooled/ 55@Water Cooled |
Operating Temperature (°C)工作温度 | 15-30 |
Power supply (90-264VAC)供电 | 220v |
Expected lifetime (hours)寿命 | 10000 |
Warranty保修 | 1 year |
571nm激光器
(型号:LL571-200mw)
产品特点:
l 功率稳定、可调节,操作简便;
l 采用原装进口 LD,性能可靠,使用寿命长;
l 电源自带过热、限流保护电路,可外接高速调制;
l 适用于光谱分析、材料分析、生物工程、光电检测、医疗等。
Wavelength (nm)波长 | 571±1 |
Operating mode输出方式 | CW |
Output power (mW)输出功率 | 1-200 |
Power stability (rms, over 4 hours)功率稳定性 | <5%, <3% |
Transverse mode光斑模式 | Near TEM00 |
Beam diameter at the aperture (1/e2, mm)光斑尺寸 | 4
|
Beam divergence (mrad)发散角 | <3 |
Cooled method制冷 | Fan Cooled/ Water Cooled |
Warm-up time (minutes)预热时间 | <10 |
Beam height from base plate (mm)中心高 | 91@Fan Cooled/ 55@Water Cooled |
Operating Temperature (°C)工作温度 | 15-30 |
Power supply (90-264VAC)供电 | 220v |
Expected lifetime (hours)寿命 | 10000 |
Warranty保修 | 1 year |
577nm窄线宽激光器
LLLM577-200mw
Wavelength (nm)波长 | 577±2 |
Operating mode输出方式 | CW |
Output power (mW)功率 | 1-200 |
Power stability (rms, over 4 hours)功率稳定性 | <3%, <2%, < 1% |
Transverse mode光斑模式 | TEM00 |
Spectral line width (nm)线宽 | <0. 1, <0.003 |
Noise of amplitude (rms, 1Hz~20MHz)性噪比 | < 1% |
M2 factor 光束质量 | < 1.2 |
Beam diameter at the aperture ( 1/e2, mm)光斑 | < 1.0 |
Beam divergence, full angle (mrad)发散角 | < 1.5 |
Polarization Ratio偏振比 | > 100:1, Horizontal (Vertical Optional) |
Warm-up time (minutes)上升时间 | <5 |
Pointing stability after warm-up (mrad)光斑指向稳定性 | <0.05 |
Beam height from base plate (mm)出光高度 | 27.4 |
Operating Temperature (°C)工作温度 | 10-35 |
Power supply (90-264VAC)供电 | 220v数显可调 |
Expected lifetime (hours)使用寿命 | 10000 |
Warranty保修 | 1 year |
577nm激光器
LL577-1200mw
LD PUMPED ALL-SOLID-STATE YELLOW LASER AT 577nm All solid state 577 nm yellow laser is made features of ultra compact, long lifetime and easy operating, which is widely used in collimation, laser medical treatment, scien
Part number | LL577-1200mw |
Wavelength (nm) | 577±2 |
Operating mode | CW |
Output power (mW) | 600- 1200 |
Power stability (rms, over 4 hours) | <3%, <2%, < 1% |
Transverse mode | Multi mode |
M2 factor | <2.0 |
Beam diameter at the aperture ( 1/e2, mm) | <2.5 |
Beam divergence, full angle (mrad) | < 1.5 |
Polarization Ratio | > 100:1, (Horizontal or Vertical Optional) |
Warm-up time (minutes) | <5 |
Pointing stability after warm-up (mrad) | <0.05 |
Beam height from base plate (mm) | 27.4 |
Operating Temperature (°C) | 10-35 |
Modulation option | TTL on/off, 1Hz- 1kHz, 1kHz- 10kHz |
Power supply (90-264VAC) | PSU-H-LED |
Expected lifetime (hours) | 10000 |
Warranty | 1 year |
579nm激光器
LL579-250mw
LD PUMPED ALL-SOLID-STATE Q-SWITCHED YELLOW LASER at 577nm CNI’s All solid state Q-switched yellow laser at 579nm has the features of ultra compact, easy operating, it is widely used in micro-electronics, metrology and material processing ,laser medical treatment, scientific
Central wavelength (nm) | 579±2 |
Operating mode | Acousto-Optic Q-switched |
Average power (mW) | 1-250 |
Rep. rate (kHz) | 10 |
Pulse duration (ns) | < 15 |
Single pulse energy (μJ) | 1~25 |
Peak power(kW) | 1.7 |
Beam diameter at the aperture ( 1/e2, mm) | <3 |
Beam divergence, full angle (mrad) | <2 |
Power stability (rms, over 4 hours) | <3%,5% |
Beam height from base plate (mm) | 120 |
Warm-up time (minutes) | < 10 |
Cooled method | Air Cooled |
Power supply | PSU-AOM (3U) |
Expected lifetime (hours) | 10000 |
Warranty period | 1 year |
582nm激光器
LL582-100mw
LD PUMPED ALL-SOLID-STATE YELLOW LASER All solid state at 582nm blue laser features of ultra compact, long lifetime, low cost and easy operating, which is used in laser display, medical treatment, scientific research, etc.
Wavelength (nm) | 582±2 |
Operating mode | CW |
Output power (mW) | > 10, 20, ..., 100 |
Power stability (rms, over 4 hours) | <3%, <5% |
Transverse mode | Near TEM00 |
Beam divergence, full angle (mrad) | <3 |
Beam diameter at the aperture ( 1/e2,mm) | ~4 |
Polarization ratio | > 100:1 |
Beam height from base plate (mm) | 100 |
Warm-up time (minutes) | < 10 |
Operating temperature (C) | 15~30 |
Power supply (90-264VAC) | PSU-W-FDA |
Expected lifetime (hours) | 10000 |
Warranty period | 1 year
|
585nm激光器
(型号:LL585-50mw)
产品特点:
l 功率稳定、可调节,操作简便;
l 采用原装进口 LD,性能可靠,使用寿命长;
l 电源自带过热、限流保护电路,可外接高速调制;
l 适用于光谱分析、材料分析、生物工程、光电检测、医疗等。
Part number型号 | LL585-50mw |
Wavelength (nm)波长 | 585±1 |
Operating mode工作方式 | CW |
Output power (mW)功率 | 1-50 |
Power stability (rms, over 4 hours)功率稳定性 | <3%, |
Transverse mode光斑模式 | Near TEM00 |
M2 factor光束质量 | <2.0 |
Beam diameter at the aperture (1/e2, mm)光斑尺寸 | <1.0 |
Beam divergence (mrad)发散角 | <1.5 |
Polarization Ratio偏振比 | >100:1, Horizontal (Vertical Optional) |
Warm-up time (minutes)预热时间 | <5 |
Pointing stability after warm-up (mrad)光束指向稳定性 | <0.05 |
Beam height from base plate (mm)中心高 | 27.4 |
Laser head consumption(W)功耗 | 15 (typical) , <25 (40℃) |
Max. Laser Head Base plate Temp (°C)工作温度 | 50 |
Operating Temperature (°C)工作温度 | 10-35 |
Modulation optional调制频率 | TTL on/off, 1Hz-1kHz, 1kHz-10kHz |
Power supply (90-264VAC)供电 | 220v |
Expected lifetime (hours)寿命 | 10000 |
Warranty保修 | 1 year |
588nm窄线宽激光器
LLRM588-200mw
Wavelength (nm)波长 | 588±2 |
Operating mode输出方式 | CW |
Output power (mW)功率 | 1-200 |
Power stability (rms, over 4 hours)功率稳定性 | <3% , <2%, < 1%, <0.5% |
Transverse mode光斑模式 | TEM00 |
Spectral line width (nm)线宽 | <0. 1, <0.003 |
Noise of amplitude (rms, 1Hz~20MHz)性噪比 | < 1%, <0.5% |
M2 factor 光束质量 | < 1.2 |
Beam diameter at the aperture ( 1/e2, mm)光斑 | < 1.0 |
Beam divergence, full angle (mrad)发散角 | < 1.5 |
Polarization Ratio偏振比 | > 100:1, Horizontal (Vertical Optional) |
Warm-up time (minutes)上升时间 | <5 |
Pointing stability after warm-up (mrad)光斑指向稳定性 | <0.05 |
Beam height from base plate (mm)出光高度 | 27.4 |
Operating Temperature (°C)工作温度 | 10-35 |
Power supply (90-264VAC)供电 | 220v数显可调 |
Expected lifetime (hours)使用寿命 | 10000 |
Warranty保修 | 1 year
|
588nm激光器
型号:LL588-1000mw
产品特点:
l 操作简便,功率可调
l 采用原装进口 LD,性能可靠,使用寿命长;
l 适用于光谱分析、材料分析、生物工程、光电检测、医疗等。
l 性能参数:
波长 Wavelength (nm) | 588+/-1nm |
输出功率 Output Power (mW) | 1-1000mw可调 |
工作方式 Operating Mode | CW |
光斑模式 Transverse Mode | near TE00 |
光束发散角 Beam Divergence (full angle, mrad) | 2mrad |
光束直径 Beam Diameter at Aperture (mm) | 3mm |
光束指向稳定性 Beam pointing stability(mrad) | <0.05 |
功率稳定性 Power Stability (RMS, over 4 hours) | <3% |
激光头 Laser Head | 尺寸 Dimensions (L×W×H, mm) |
|
供电方式 Power Supply | 220v可调 |
预热时间 Warm-up Time (minutes) | <5 |
工作温度 Operation Temperature (℃) | 10~40 |
使用寿命 Expected Lifetime (hours) | >10000 |