8-Channel Valve-Pressure Controller, with precision TimerComputerized controller for pinch and fast solenoid valves. Generates pressure up to 15 PSI and allows to switch solution application with 10ms accuracy (an external pressure source is required for higher pressure up to 100PSI - see table below). No syringe stands or sources of pressure are required. To make a functional system add PV-V-ADD valves below (add valves according to the number of channels required, ships installed in an aluminum box - no electrical noise during switching). Can be used with small delivery manifold SVDS1 and pressure cylinders PC. Comes with wireless remote control. The controller opens valves through manual switches, wireless remote or by TTL signals generated by a computer or other equipment. Other control options include: open valves by analog signal, and through RS232 port (or USB connection). Compatible with data acquisition and imaging systems. Optional software to generate solution switching sequences to automate complex routine protocols is available. Incorporates INHIBIT mode: to CLOSE channels simultaneously, and CODE mode: to operate by limited number of digital INPUT signals. Can be configured to work with external source of pressure to generate higher output pressure (on request only).
AUTO Memory The controller can operate in Auto Memory mode, when a set of chosen valves opens automatically at the time the other valves close. This is useful for automatic switching to control solutions after the test solution is OFF. Digital input Optically isolated inputs for each channel. BNC connector for TTL inputs and DB-9 connector. CODE Mode The controller has an options for valves control by channel encoding using only 2-4 digital inputs, in case if a limited number of digital outputs is available in your system. Analog Input You can also use analog signal input to switch the channels by changing the voltage (0.5V increment). USB/RS232 Input The RS232 port allows automation of solution switching and integration with imaging systems. Analog Out Analog output to switch outflow automatically, or to use as a mark on your recordings (can be configured for telegraph output). INHIBIT Mode Closes valves regardless of input. Negative INPUTs Optional modification to use TTL inputs to close channels in response to the time sequence pulses. Used in certain applications when continuous flow through the channel is required, with short CLOSED periods. DIMENSIONS Size: 2.7 x 12 x 9in. Includes 120/220VAC external power supply. |
||||||||||||||||||||||||||||
The analog output can be used to turn OUTFLOW automaticallyShown is a miniature flow control unit, which can drive solution up to 22ml/min. Specify analog option for automatic outflow when perfusion is turned ON. Click on image to enlarge. Another option is to use the analog output as a telegraph signals to monitor the channels. |
||||||||||||||||||||||||||||
Optional accessories: small volume delivery system, micromanifold, pressure cylinders, pressure adapter. Download PDF catalog. |
||||||||||||||||||||||||||||
|
一家集进口科研仪器代理销售以及实验技术服务于一体的高新技术公司。专注生物力学和3D生物打印国际前沿科研设备代理销售及科研实验项目合作服务,内容涵盖了血管力学生物学、…... 了解更多>>