美国肯特coda单动物单通道以及多动物多通道尾袖套法无创血压系统(Non-Invasive Blood Pressure System - Tail Cuff Method)
KENT公司CODA系列无创血压、血流测量系统,采用世界上最先进的第三代传感器技术----容量压力记录法(VPR)。容量压力记录传感器运用一种特别设计的压差传感器装置,无创测量小动物尾巴的血流参数。
KENT公司CODA血压可以同时直接测量六道血液参数: 心脏收缩的血压、舒张血压、平均压、脉搏率、尾部血液容量和尾部血流速。
与传统方法的区别:
1、运用最新容量压力记录法(VPR) 传感器技术测量老鼠或鼠尾巴血压。
2、我们的VPR 技术根据鼠尾巴血液容量''实际测量舒张血压。而其他产品的测量结果是通过计算得来的。
3、容量压力记录法运用测量血液容量方法测量尾巴血流和血液容量的变化''不受环境光的影响,皮肤染色分类的动物也没有影响,更没有人为计算的误差,也基本不受动物轻微运动变化影响。甚至体重非常小''例如 10克C57/BL6 黑老鼠也可以容易地测量。
特殊设计袖带、探头设计:保证获得最准确的血压读数。
容量压力录音是最可靠'' 相关性好和准确,可以无创地直接测量老鼠血压。在Yale University''New Haven'' Connecticut独立临床检验研究中心'' 进行容量压力记录法和有创测量血压的相关性达到百分之99。
适用范围:小于10 克的小鼠,到大于950 克的超大鼠。
coda多动物多通道2通道)尾袖套法无创血压系统(Non-Invasive Blood Pressure System - Tail Cuff Method):
一、coda两通道的尾袖套法无创血压系统,配置和图如下:
二、coda 四通道的尾袖套法无创血压系统,配置和图如下
6 blood pressure parameters: systolic diastolic and mean BP heart rate tail blood volume and blood flow
The CODA? mouse rat tail-cuff system was designed to allow you to accurately measure mouse blood pressure and rat blood pressure. The CODA tail-cuff blood pressure system utilizes Volume Pressure Recording (VPR) sensor technology to measure the mouse or rat tail blood pressure.
VPR recording is clinically validated and provides 99% correlation with telemetry and direct blood pressure measurements. Only our VPR technology is based on mouse and rat tail blood volume and can actually measure the diastolic blood pressure. All other tail-cuff technologies estimate (calculate) the diastolic blood pressure in mice and rats.
Click here to see how Volume Pressure Recording reduces your animal's stress level
when compared to photoplethysmography (PPG).
The software allows you to continuously view data in real-time.
The animal nose cone holders that accompany the CODA NIBP system were specifically designed for non-invasive tail blood pressure measurements. The clear acrylic holders provide unrestricted breathing and allow complete visibility to the researcher.
The VPR sensor incorporates a specially designed differential pressure transducer that measures the systolic and diastolic blood pressure by determining the blood volume in the tail. We have sizes for mice as small as 8 grams to rats as large as 950 grams.
Click here to access our database of researchers who trust the CODA mouse rat blood pressure system for their published research. For your convenience'' the database is broken down by animal type and application.
Click here to see what your colleagues are saying about Volume Pressure Recording!
coda''多动物多通道2通道)尾袖套法无创血压系统(Non-Invasive Blood Pressure System - Tail Cuff Method)配置如下:
三、coda 六通道的尾袖套法无创血压系统,配置如下
四、coda 八通道的尾袖套法无创血压系统,配置如下