HH-BLQ玻璃微球总烃柱应用在…

HH-BLQ玻璃微球总烃柱应用在安捷伦岛津赛默飞瓦里安布鲁克PE
产品简介
详细介绍
  • 参考报价:电议 产地:山东 品牌:浩瀚 型号:HH-BLQ 更新时间:2024/12/21

HH-BLQ玻璃微球总烃柱应用在安捷伦岛津赛默飞瓦里安布鲁克PE

HH-BLQ玻璃微球总烃柱应用在安捷伦岛津赛默飞瓦里安布鲁克PE 详细信息:


名称:玻璃微球总烃柱
规格:2m*3mm
编号:20241011003

zui高使用温度:300°C

应用:安捷伦4890,5890,6890,7820A,7890B,8860,8890;岛津GC7C,GC-14C,GC-2010,GC-2014,GC-2018,gc-2030;赛默飞1310系列,布鲁克456,PE580,,瓦里安3400,磐诺a90,福立9700,北分瑞利3400,东西电子4000A,天瑞,天美,科创,华爱,科晓/捷岛,川仪等实验室/便携式/ 在线/VOCS/NMHC

分离:

HJ1999/HJ2017固定污染源废气中总烃,甲烷,非甲烷总烃的测定  气相色谱法

HJ2011/HJ2017环境空气中总烃,甲烷,非甲烷总烃的测定 气相色谱法


总烃峰型对称,不分叉,柱效高


浩瀚色谱,依据《固定污染源废气总烃、甲烷和非甲烷总烃的测定便携式气相色谱—氢火焰离子化检测器法》(HJ 1332—2013)

质量控制要求,测定非甲烷总烃的方法,柱效高,分离好,结果满意。


HH-BLQ玻璃微球总烃柱应用在安捷伦岛津赛默飞瓦里安布鲁克PE 图片:




Application of HH-BLQ glass microsphere total hydrocarbon column in Agilent Shimadzu Thermo Fisher Valianbrook PE




Application of HH-BLQ Glass Microsphere Total Hydrocarbon Column in Agilent Shimadzu Thermo Fisher Valianbrook PE Details:






Name: Glass Microsphere Total Hydrocarbon Column


Specification: 2m * 3mm


Number: 20241011003


Maximum operating temperature: 300 ° C




Application: Agilent 4890589068907820A, 7890B, 88608890; Shimadzu GC7C, GC-14C,GC-2010,GC-2014,GC-2018,gc-2030; Thermo Fisher 1310 series, Brooke 456, PE580,, Varian 3400, Panno a90, Fuli 9700, Beifen Ruili 3400, Dongxi Electronics 4000A, Tianrui, Tianmei, Kechuang, Huaai, Kexiao/Jiedao, Chuanyi and other laboratories/portable/online/VOCS/NMHC




Separation:




HJ1999/HJ2017 Determination of Total Hydrocarbons, Methane, and Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources Gas Chromatography Method




HJ2011/HJ2017 Determination of total hydrocarbons, methane, and non methane total hydrocarbons in ambient air by gas chromatography method






The total hydrocarbon peak is symmetrical, non branched, and has high column efficiency






Haohan Chromatography, based on the portable gas chromatography hydrogen flame ionization detector method for the determination of total hydrocarbons, methane, and non methane total hydrocarbons in fixed pollution source exhaust gas (HJ 1332-2013)




Quality control requirements: The method for determining non methane total hydrocarbons has high column efficiency, good separation, and satisfactory results.






Application of HH-BLQ glass microsphere total hydrocarbon column in Agilent Shimadzu Thermo Fisher Scientific Valianbrook PE image


单位名称:浩瀚色谱(山东)应用技术开发有限公司
详细地址:滕州市(商务部和技术部);
QQ:1404939462
联系手机:
联系电话:
我要咨询:我要咨询
传真:0632-5667636
Email:1455546473@qq.com