M8MJSS-18-U-6_M8MJSS-18-U…

M8MJSS-18-U-6_M8MJSS-18-U-9_M8MJSS-18-U-12热电偶探头OMEGA欧米茄
产品简介
详细介绍
  • 参考报价:电议 产地:美国 品牌:德威尔 型号:M8MJSS-18-U-6 更新时间:2021/5/25

M8MJSS-18-U-6_M8MJSS-18-U-9_M8MJSS-18-U-12热电偶探头OMEGA欧米茄

提供“J”型和304不锈钢护套,或“K”型和铬镍铁合金600护套。


仅在单元素配置中可用。


不接地连接是标准的,可选的接地连接传感器也可用。


可提供1/8“ANSI色标和2 mm和3 mm IEC色标探头直径。


IP67带热电偶补偿销的成型M8连接器


也可选择二次成型的M8热电偶延长电缆。

M8MJSS-18-U-6_M8MJSS-18-U-9_M8MJSS-18-U-12热电偶探头OMEGA欧米茄

The M8M series of small diameter thermocouple probes with M8 connectors can be used where other sensors can't. Their smaller size allows for measurements in tight spaces, or when you need to have a minimal impact on the thermal environment that you are measuring.

These thermocouple sensors are available in Type J with 304 stainless steel sheaths, or in Type K with Inconel 600 sheaths. The 1/8" diameter version is overmolded in the ANSI color code and is available in 6", 9" and 12" lengths. The 2 mm and 3 mm diameter versions are molded in the IEC color code and is available in 150, 200 and 250 mm lengths.

The connector pin out is as shown in the accompanying figure. To maintain the proper polarity and the use of thermocouple materials from the sensor to your measurement or control instrument, we recommend one of Omega's M8 Thermocouple Extension Cables (listed in the ordering table below).

Specifications:

  • Type J Thermocouples have a 304 SST sheath with a temperature range of -40 to 600°C, with the connector overmolded in black nylon.

  • Type K Thermocouples have an Inconel 600 sheath with a temperature range of -40 to 1150°C, with the connector overmolded in yellow nylon on the 1/8" diameter version, and green nylon on the 2mm and 3mm diameter versions.

  • Note: Molded connectors have a maximum temperature of 90°C.

  • Thermocouple output is per IEC 584-2, Class 2.

  • Fractional sizes are available with 1/8" diameter x 6", 9" or 12" long probes.

  • Metric sizes are available with 2mm or 3mm diameter x 150, 200 or 250mm long probes.

  • Insulation Resistance is 100 megohms at 100VDC for ungrounded sensors.

  • Minimum Bend Radius is three times the outer probe diameter.



  • Connect your M8 thermocouple probe to one of Omega's wide variety of in-stock controllers, data loggers, hand held thermometers, PLCs or other measurement or process control products to complete your measurement or control system.

M8MJSS-18-U-6_M8MJSS-18-U-9_M8MJSS-18-U-12热电偶探头OMEGA欧米茄

单位名称:上海茂培电子科技有限公司
详细地址:金海路2588号1幢B219室
QQ:1059980451
联系手机:
联系电话:
我要咨询:我要咨询
传真:
Email:sales@mp-shanghai.com