测量原理 | 静压 |
特点 | Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell: - hermetically welded - absolute condensation tight - climate-resitant - long-term stable - Lowest temperature influences
Cable version
|
电源/通信 | 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
|
测量精度 | Standard 0,2% Optional 0,1%
|
长期稳定性 | 0,05% of URL/year
|
过程温度 | PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F
|
环境温度 | -40°C...85°C (-40°F...185°F)
|
量程 | 100 mbar...10 bar (1.5 psi...150 psi)
|
Smallest calibratable span | 10 mbar (1.45 psi)
|
Vacuum resistance | 0 mbar abs.
|
开关比 | 100:1
|
最大过压极限 | 40 bar (600 psi)
|
过程连接 | Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K
|
Material process membrane | 316L, AlloyC, Gold-Rhodium PE, FEP
|
Material gasket | Viton, EPDM, Kalrez, none
|
Fill fluid | Inert oil, Synthetic oil
|
Material housing | 316L, Die-cast aluminum
|
输出 | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
证书和认证 | ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
|
Safety approvals | Overfill prevention WHG SIL
|
Design approvals | EN10204-3.1 NACE MR0175
|
Marine approvals | GL/ ABS/ LR/ BV/ DNV
|
Drinking water approvals | KTW/ NSF/ ACS
|
特性 | Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions
Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed) |