测量原理 | 涡街 |
主要特点 | The flowmeter with a cost‐effective wafer design, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1‐to‐1 replacement of orifice plates.
|
特点 | Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Face‐to‐face length of 65 mm (2.56 in). No flanges.
|
Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual‐compartment housing.
|
直径 | DN 15 to 150 (? to 6")
|
Wetted materials | Measuring tube: 1.4408 (C3FM) DSC sensor: 1.4435 (316/316L)
|
Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
测量误差 | Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 %
|
量程 | Liquid: 0.16 to 625 m3/h (0.09 to 368 ft3/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m3/h (1.18 to 4910 ft3/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
压力范围 | PN 40, Class 300, 20K
|
过程温度 | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
|
环境温度 | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L)
|
电子插件的防护 | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
|
显示/操作 | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
输出 | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
输入 | Current input 4‐20 mA (passive)
|
通信 | HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply | DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
防爆认证 | ATEX, IECEx, cCSAus, TIIS
|
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TüV attestation)
|
Pressure approvals and certificates | PED, CRN
|
Material certificates | 3.1 material NACE MR0175/MR0103, PMI (on request) |