Microsaic3500MiD芯片质谱仪…

Microsaic3500MiD芯片质谱仪
产品简介
详细介绍
  • 参考报价:电议 产地:英国 品牌:无 型号:Microsaic 3500 MiD 更新时间:2023/4/3

特性:

Microsaic Systems公司推出的全球首款基于芯片的质谱仪Microsaic 3500 MiD

英国新一代质谱仪技术开发商——Microsaic Systems公司在德国慕尼黑举办的分析、生化及实验室技术展(Analytica

2012)期间展出全球首款基于芯片的质谱仪Microsaic 3500 MiD。

  据悉,该款质谱仪由三大制药公司合作开发,较常规质谱仪小90%。Microsaic Systems公司已通过将关键的微型元件与专利的芯片技术相结合,成功地改变了质谱分析法。其核心技术是传统质谱组件的芯片级版本。3500 MiD也是目前市面上唯一一款不需要外部真空泵的质谱系统。

  另悉,该质谱仪的设计旨在与现有的高效液相色谱设备集成,无需额外封装及基础设施。3500 MiD也可与Prep LC、Flash LC和SFC等其它分离方法结合。

简介:

The Microsaic 3500 MiD is the world’s smallest fully integrated MS system. The 3500 MiD is the size of a standard desktop computer and with very few additional infrastructure requirements it is smaller, lighter, more energy efficient and cheaper to run than conventional MS systems.

The 3500 MiD is designed to readily integrate with existing HPLC equipment with no extra footprint extending the capability of your HPLC system with significant cost savings compared to a conventional MS system.

Historically, MS has only been used for off-line analysis but the 3500 MiD is so compact it can be used for on-line reaction monitoring in a fume-hood. Monitoring batch reactions in real time provides the chemist with vital reaction data which can be acted upon to maximise yield and/or minimize impurities. The 3500 MiD is also ideal for flow chemistry systems where MS data can be used for faster reaction optimisation.

The system is portable with modular plug and play components for maximum application flexibility.

特点:

SMALLEST FOOTPRINT IN THE MARKET

Far smaller than conventional mass spectrometers, with fewer infrastructure requirements (e.g. sound- proofing, floor pump, UPS, gas generator) the Microsaic 3500 MiD is a versatile, portable solution designed for bench chemists.

STACKABLE, ONE BOX SOLUTION

Designed to integrate with existing equipment with no extra footprint.

CHIP-BASED MASS SPECTROMETRY

The 3500 MiD is a fully integrated MS system. The core technologies are chip-scale versions of traditional mass spec components which can be interchanged rapidly by the user. This modular approach allows users to maintain the system without the need for expensive service contracts and time-consuming call-outs.

spraychip®

Microspray ionisation source

vac-chip™

Micro-engineered vacuum interface

ionchip®

Chip-based quadrupole mass analyzer

CHANGE THE CHIP AS YOUR NEEDS CHANGE!

‘Plug and play’ chips make the 3500 MiD configurable, flexible and future proof.

MASSCAPE™ SOFTWARE

The 3500 MiD runs Masscape; an intuitive, open-access software for method development and LC-MS.

DATA ANALYSIS.

Masscape may be used off-line as a data analysis solution. Masscape files are in a variety of formats including NetCDF, compatible with software from major LC companies.

SAVE MONEY

10% of the running costs of conventional MS systems. Big savings on costly infrastructure such as gas generators, air-con and UPS.

MINIMAL DOWNTIME

‘Plug and play’ components allow users to maintain the system. Zero call outs.

NETWORK READY

Remote control via LAN connection removes the need for a monitor or keyboard, further minimizing footprint: ideal for fume-hood deployment.

PHYSICAL REQUIREMENTS

Dimensions

60 cm * 35 cm * 18.5 cm (L) * (W) * (H)

Weight

27 kg

HARDWARE

Ion Source

spraychip®

Ionization Modes

Positive and negative ESI

Sample Inlet

Compatible with standard LC capillarys and unions e.g. 1/16" tubing

Direct Flow Rate

0.2µL/min - 1µL/min

Split Flow Rate

1µL/min – 1.8ml/min

Mass Analyzer

ionchip® quadrupole mass spectrometer

Mass Range

80-800 m/z with ionchip®150

Mass Accuracy

±0.3 m/z

Mass Resolution

0.7 FWHM

Sensitivity

10pg with a S/N of 10:1 rms in SIM mode using a 1µL injection of Reserpine at 150µL/min

Spectrum Display

Continuum (profile) and Centroid (stick)

Vacuum Interface

vac-chip™ microengineered API

Detector

Electron multiplier

Dynamic Range

3 orders of magnitude

Scan Modes

Full scan or 8 m/z channels (SIM)

Scan Rate

Up to 3,600 pts/s

Pumping System

Integrated maintenance-free pumps.

Computer

Integrated on-board computer

Operating System

Linux Open Source

Connectivity

Ethernet, 3 x USB
4 x digital I/O (e.g. LC trigger input)
2 x analog I/O
1 x RS232 (e.g. syringe pump control)

ENVIRONMENTAL REQUIREMENTS

Operating

10-35 °C with 40%~80% relative humidity noncondensing.
Sea-level to 2,000m

Storage


 

-20-70 °C with 0%~90% relative humidity noncondensing

REGULATORY COMPLIANCE

Safety


 

IEC 61010-1: 2001
UL 61010-1:2004
CSA C22.2 61010-1-04
IEC/EN 61326:2006
EN 61000-3-2:20006
+A1:2009
+A2:2009
EN61000-3-3 :2008
ICES-003 :2004
FCC CFR 47:Part 15:B:2008

MASSCAPE™ SOFTWARE

The Masscape™ software application gives you full control of the data acquisition and analysis of your chemical samples.

Data Capture

Mass spectra (profile and centroid) selected ion monitoring modes (SIM)

Data Analysis


 

Peak integration
Noise subtraction
Base peak chromatogram (BPC)
Extracted ion chromatogram (EIC)
Labeling and annotations

Chromatogram

Retention time, peak height and area (integrated chromatogram)

Mass Spectrum

m/z and intensity profile or centroid

Data Input

Real-time analog input of UV trace and display in Masscape

Data Output

Real-time analog output of TIC or SIM trace

Data Export

NetCDF, Excel, CSV
Data interchange via USB or LAN

Configuration


 

May be controlled remotely over LAN. External trigger allowing automatic analysis of samples via a method table.

UTILITY REQUIREMENTS

Power


 

200 W (operating) 300 W (peak)
Line voltage: 100-240 V AC
Line frequency 50/60 Hz

Nitrogen Gas


 

Pressure 2- 6 bar (29 – 87 psi)
Purity (99.5%)

Pump Exhaust

Exhaust connects to 2 * 8 mm OD push fit bulkhead connections

规格说明:

PHYSICAL REQUIREMENTS

Dimensions

60 cm * 35 cm * 18.5 cm (L) * (W) * (H)

Weight

27 kg

HARDWARE

Ion Source

spraychip®

Ionization Modes

Positive and negative ESI

Sample Inlet

Compatible with standard LC capillarys and unions e.g. 1/16" tubing

Direct Flow Rate

0.2µL/min - 1µL/min

Split Flow Rate

1µL/min – 1.8ml/min

Mass Analyzer

ionchip® quadrupole mass spectrometer

Mass Range

80-800 m/z with ionchip®150

Mass Accuracy

±0.3 m/z

Mass Resolution

0.7 FWHM

Sensitivity

10pg with a S/N of 10:1 rms in SIM mode using a 1µL injection of Reserpine at 150µL/min

Spectrum Display

Continuum (profile) and Centroid (stick)

Vacuum Interface

vac-chip™ microengineered API

Detector

Electron multiplier

Dynamic Range

3 orders of magnitude

Scan Modes

Full scan or 8 m/z channels (SIM)

Scan Rate

Up to 3,600 pts/s

Pumping System

Integrated maintenance-free pumps.

Computer

Integrated on-board computer

Operating System

Linux Open Source

Connectivity

Ethernet, 3 x USB
4 x digital I/O (e.g. LC trigger input)
2 x analog I/O
1 x RS232 (e.g. syringe pump control)

ENVIRONMENTAL REQUIREMENTS

Operating

10-35 °C with 40%~80% relative humidity noncondensing.
Sea-level to 2,000m

Storage


 

-20-70 °C with 0%~90% relative humidity noncondensing

REGULATORY COMPLIANCE

Safety


 

IEC 61010-1: 2001
UL 61010-1:2004
CSA C22.2 61010-1-04
IEC/EN 61326:2006
EN 61000-3-2:20006
+A1:2009
+A2:2009
EN61000-3-3 :2008
ICES-003 :2004
FCC CFR 47:Part 15:B:2008

MASSCAPE™ SOFTWARE

The Masscape™ software application gives you full control of the data acquisition and analysis of your chemical samples.

Data Capture

Mass spectra (profile and centroid) selected ion monitoring modes (SIM)

Data Analysis


 

Peak integration
Noise subtraction
Base peak chromatogram (BPC)
Extracted ion chromatogram (EIC)
Labeling and annotations

Chromatogram

Retention time, peak height and area (integrated chromatogram)

Mass Spectrum

m/z and intensity profile or centroid

Data Input

Real-time analog input of UV trace and display in Masscape

Data Output

Real-time analog output of TIC or SIM trace

Data Export

NetCDF, Excel, CSV
Data interchange via USB or LAN

Configuration


 

May be controlled remotely over LAN. External trigger allowing automatic analysis of samples via a method table.

UTILITY REQUIREMENTS

Power


 

200 W (operating) 300 W (peak)
Line voltage: 100-240 V AC
Line frequency 50/60 Hz

Nitrogen Gas


 

Pressure 2- 6 bar (29 – 87 psi)
Purity (99.5%)

Pump Exhaust

Exhaust connects to 2 * 8 mm OD push fit bulkhead connections

世联博研北京科技有限公司是英国Microsaic Systems在中国授权代理商,咨询、索取产品资料请致电010-67529703

单位名称:世联博研(北京)科技有限公司
详细地址:北京市海淀区西三旗上奥世纪中心A座9层906
QQ:736597338
联系手机:
联系电话:
我要咨询:我要咨询
传真:010-67529703
Email:slby800@163.com