华仪7151/7152/7160/7162耐…

华仪7151/7152/7160/7162耐压测试仪
产品简介
详细介绍
  • 参考报价:电议 产地:台湾 品牌:华仪 型号:华仪7151/7152/7160/716 更新时间:2012/12/25

华仪7151/7152/7160/7162耐压测试仪

  特点
体积小 (28宽 × 8.9高 × 30深 cm) 、重量轻 8.4kg
四种测试顺序可供选择:W, I, W-I, I-W (Only 7152 , 7162)
可与华仪的接地阻抗测试仪7305连结使用
内建10组程序内存
缓升及测试时间可达999.9秒
键盘锁定功能
内建PLC Remote可程序遥控界面
前面板软件输入校正
操作简单
 

技术参数

MODEL 7151 7152 7160 7162
AC WITHSTAND VOLTAGE
Output Rating
5KVAC/12mA
 
Range
Resolution
Accuracy
Output Voltage, KVAC
0-5.00
0.01
±(2% of setting + 5V)
Output Frequency 50Hz/60Hz ±100ppm, User Selection
Output Waveform Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5
Output Regulation ± (1% of output + 5V), From no load to full load
SETTINGS
Hi-Limit AC Current, mA
0.10 - 12.00
0.01
±(2% of setting + 2counts)
Lo-Limit AC Current, mA
0.00 - 12.00
0.01
±(2% of setting + 2counts)
Ramp Time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
Dwell Time, second
0, 0.2 - 999.9
(0=continuous)
0.1
Arc Detection 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity)
DC WITHSTAND VOLTAGE (7160,7162 ONLY)
Output Rating
6KVDC/5mA
Output Voltage, KVDC
0 - 6.00
0.01
±(2% of setting + 5V)
Output Ripple <5%(6KV/5mA at Resistive Load)
SETTINGS
Hi-Limit DC Current, mA
0.02 - 5.00
0.01
±(2% of setting + 2counts)
Lo-Limit DC Current, mA
0.00 - 5.00
0.01
±(2% of setting + 2counts)
Ramp Time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
Dwell Time, second
0, 0.2 - 999.9
(0=continuous)
0.1
Arc Detection 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity)
Discharge Time < 200 msec
INSULATION RESISTANCE (7152,7162 ONLY)
Output Rating
1KVDC/1000MΩ
Output Voltage, KVDC
0.10 - 1.00
0.01
±(2% of setting + 3V)
SETTINGS
Hi-Limit Resistance, MΩ
0, 1 - 1000 (0=OFF)
1
±(3% of setting+2counts)at > 500VDC
Lo-Limit Resistance, MΩ
1 - 1000
1
±(7% of setting +2counts)at <500VDC
Delay Time, second
0, 0.5 - 999.9
(0=continuous)
0.1
±(0.1% + 0.05sec)
MEASUREMENT
AC/DC Voltage, KV
0 - 6.00
0.01
±(1.5% of reading + 1count)
DC Voltage, KV (IR only)
0.10 - 1.00
0.01
±(1.5% of reading + 3V)
AC Current, mA
0.10 - 12.00
0.01
±(2% of reading + 2counts)
DC Current, mA
0.02 - 5.00
0.01
±(2% of reading + 2counts)
Resistance, MΩ
1 - 1000
(Auto Range)
0.001
0.01
0.1
±(3% of reading+2counts)at > 500VDC
±(7% of reading +2counts)at <500VDC
GENERAL
Input Voltage AC 115/230Vac±15%, 50/60Hz ± 5%, Fuse 3.15A Fast
PLC Remote Control Input : Test , Reset
Output : Pass , Fail , Processing
Memory 10 Sets Store/Recall of each Memory, 4 Test Mode Selectable (W, I, W~I, I~W Only 7152, 7162)
Display 16×2 LCD with back light
Key Lock To prevent unauthorized alteration of the test Parameters
Calibration Build-in software and external calibrated meters
Environment 0-40℃, 20-80%RH
Dimension/Net Weight 280mm(W)×89mm(H)×300mm(D)/ 8.4Kg
STANDARD ACCESSORIES
Power Cord(10A)
×1
Fuses
×3 (Including a spare contained in the fuse holder)
Hipot Test Lead ,1.5m(1101)
×1
Hipot Return Lead ,1.8m(1102)
×1
*product specifications are subject to change without notice.

华仪7151/7152/7160/7162耐压测试仪

 

  特点
体积小 (28宽 × 8.9高 × 30深 cm) 、重量轻 8.4kg
四种测试顺序可供选择:W, I, W-I, I-W (Only 7152 , 7162)
可与华仪的接地阻抗测试仪7305连结使用
内建10组程序内存
缓升及测试时间可达999.9秒
键盘锁定功能
内建PLC Remote可程序遥控界面
前面板软件输入校正
操作简单

 

技术参数

MODEL 7151 7152 7160 7162
AC WITHSTAND VOLTAGE
Output Rating
5KVAC/12mA
 
Range
Resolution
Accuracy
Output Voltage, KVAC
0-5.00
0.01
±(2% of setting + 5V)
Output Frequency 50Hz/60Hz ±100ppm, User Selection
Output Waveform Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5
Output Regulation ± (1% of output + 5V), From no load to full load
SETTINGS
Hi-Limit AC Current, mA
0.10 - 12.00
0.01
±(2% of setting + 2counts)
Lo-Limit AC Current, mA
0.00 - 12.00
0.01
±(2% of setting + 2counts)
Ramp Time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
Dwell Time, second
0, 0.2 - 999.9
(0=continuous)
0.1
Arc Detection 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity)
DC WITHSTAND VOLTAGE (7160,7162 ONLY)
Output Rating
6KVDC/5mA
Output Voltage, KVDC
0 - 6.00
0.01
±(2% of setting + 5V)
Output Ripple <5%(6KV/5mA at Resistive Load)
SETTINGS
Hi-Limit DC Current, mA
0.02 - 5.00
0.01
±(2% of setting + 2counts)
Lo-Limit DC Current, mA
0.00 - 5.00
0.01
±(2% of setting + 2counts)
Ramp Time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
Dwell Time, second
0, 0.2 - 999.9
(0=continuous)
0.1
Arc Detection 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity)
Discharge Time < 200 msec
INSULATION RESISTANCE (7152,7162 ONLY)
Output Rating
1KVDC/1000MΩ
Output Voltage, KVDC
0.10 - 1.00
0.01
±(2% of setting + 3V)
SETTINGS
Hi-Limit Resistance, MΩ
0, 1 - 1000 (0=OFF)
1
±(3% of setting+2counts)at > 500VDC
Lo-Limit Resistance, MΩ
1 - 1000
1
±(7% of setting +2counts)at <500VDC
Delay Time, second
0, 0.5 - 999.9
(0=continuous)
0.1
±(0.1% + 0.05sec)
MEASUREMENT
AC/DC Voltage, KV
0 - 6.00
0.01
±(1.5% of reading + 1count)
DC Voltage, KV (IR only)
0.10 - 1.00
0.01
±(1.5% of reading + 3V)
AC Current, mA
0.10 - 12.00
0.01
±(2% of reading + 2counts)
DC Current, mA
0.02 - 5.00
0.01
±(2% of reading + 2counts)
Resistance, MΩ
1 - 1000
(Auto Range)
0.001
0.01
0.1
±(3% of reading+2counts)at > 500VDC
±(7% of reading +2counts)at <500VDC
GENERAL
Input Voltage AC 115/230Vac±15%, 50/60Hz ± 5%, Fuse 3.15A Fast
PLC Remote Control Input : Test , Reset
Output : Pass , Fail , Processing
Memory 10 Sets Store/Recall of each Memory, 4 Test Mode Selectable (W, I, W~I, I~W Only 7152, 7162)
Display 16×2 LCD with back light
Key Lock To prevent unauthorized alteration of the test Parameters
Calibration Build-in software and external calibrated meters
Environment 0-40℃, 20-80%RH
Dimension/Net Weight 280mm(W)×89mm(H)×300mm(D)/ 8.4Kg
STANDARD ACCESSORIES
Power Cord(10A)
×1
Fuses
×3 (Including a spare contained in the fuse holder)
Hipot Test Lead ,1.5m(1101)
×1
Hipot Return Lead ,1.8m(1102)
×1
*product specifications are subject to change without notice.
单位名称:深圳市乐买宜电子有限公司
详细地址:深圳市宝安区福永街道凤凰社区广深路福永段109号锦灏大厦2203
QQ:997709382
联系手机:
联系电话:
我要咨询:我要咨询
传真:0755-29176598
Email:dqj@lemaiyi.com