CodeLink?HumanInflammati…

CodeLink?HumanInflammationv116-AssayBioarray(1pack)
产品简介
详细介绍
  • 参考报价:4560 产地:美国 品牌:AMB 型号:300076-1PK 更新时间:2023/4/3

 

CodeLink™ Mammalian Inflammation Bioarray Series: Human Inflammation Bioarray (#300076-1PK or 3PK) Mouse Inflammation Bioarray (#300072-1PK or 3PK) Rat Inflammation Bioarray (#300077-1PK or 3PK)

Mammalian Inflammation Bioarrays

 

The CodeLink™ Mammalian Inflammation Bioarray Series comprises three products designed for analysis of RNA expression pathway variations of a focused set of genes involved in the inflammation response. The 30-mer probe designs for the Inflammation Bioarrays were selected from the corresponding whole genome bioarrays to ensure high quality probe activity and cross-over studies from preliminary screening experiments on the whole genome counterparts. The products are offered in a multi-assay format with an attached hard-walled chamber enabling the processing of 16 samples on a single slide. These bioarrays allow for focused investigations of diseases, treatments, and/or biological states that involve an inflammation response, with a CodeLink™ high quality, cost-effective, low target requirement, and high-throughput system. The number of transcripts represented on each product varies based on the state of the genome; the exact numbers are given in the chart below.

Probe Specifications for each Mammalian Bioarray

Probe content

Human

Mouse

Rat

Total number of probes on array

1,045

994

783

Discovery Probes

905

854

643

Representing: Recommended housekeeping genes

96

96

48

Transcripts (NCBI accessions)

1497

1020

714

Genes (UniGene clusters)

1040

946

667

Positive control probes per bioarray (6 bacterial genes X 5 unique probes each @ 2X redundancy)

60

60

60

Negative control probes (32 unique bacterial probes @ 2X redundancy

64

64

64

Fiducial probes for gridding

16

16

16

Storage and Handling Conditions

Upon receipt, Mammalian Inflammation Bioarrays should be stored at room temperature in a desiccated environment.

Product Use Limitations

 

CodeLink™ Mammalian Inflammation Bioarrays are intended for research use only. Safety Precautions Standard laboratory safety procedures should be followed when using this product. Safety glasses, a lab coat, and appropriate gloves should be worn at all times when in the laboratory. All goods and services are sold subject to the terms and conditions of sale of Applied Microarrays, Inc. which supplies them. A copy of these terms and conditions is available on request.

 

 

 