武汉格莱莫检测设备有限公司 电话:13545068882 027-86619889
传真:027-86619889 网址:www.glmgs.com
一、CTS-23B超声探伤仪 产品简介
A brief introduction of product, CTS-23B ultrasonic flaw detector
该产品是携带式A型脉冲反射式超声波探伤仪,可用交流电或电池供电工作。仪器具有频带可变的宽频放大器,宽扫描范围的时基电路,设置了细调及微调的高精度衰减器;仪器采用高亮度、内刻度矩形进口示波管。探伤灵敏度高、稳定性好、波形清晰、体积小、重量轻、耗电省且操作方便。CTS-23B 型具有报警功能,可分别对闸门内的“进波”或“失波”报警。仪器适用于焊缝、锻件等金属和部分非金属材料的无损检测,特别适用于近区高分辨力探伤,可作为无损检测人员资格考核用标准化仪器。
The product is portable A type pulse reflection type ultrasonic flaw detector, available AC or battery power supply. Apparatus having a frequency variable broadband amplifier, wide scanning range of the time-base circuit, set up fine tuning and fine-tuning of the high precision attenuator; instrument uses the high luminance, inner scale rectangular inlet tube. Detection of high sensitivity, good stability, clear waves, small volume, light weight, low power consumption and convenient operation. Type CTS-23B has the alarm function, can be respectively on gate within the " waves " or" wave" alarm. Apparatus suitable for welding, forging and other metals and some non-metallic materials nondestructive testing, particularly applicable to the area near the high resolution detection, can be used as a nondestructive testing personnel qualification assessment using standardized instruments.
二、CTS-23B超声探伤仪 技术指标
In two, CTS-23B ultrasonic flaw detector technology index
★工作频率范围:0.5~20MHz,分三个频段
In the operating frequency range : 0.5 ~ 20MHz, divided into three frequency bands
★衰减器:90dB,每2dB±0.1dB
Attenuator: 90dB, each of 2dB + 0.1dB
★垂直线性误差:≤5%
Vertical linearity error: < 5%.
★动态范围:≥30dB
Dynamic range: 30dB.
★扫描范围(钢纵波):5~5000mm
In the scanning range ( steel p: 5 ~ 5000mm )
★水平线性误差:≤1%
Horizontal linearity error: < 1%.
★最小探测距离:≤1.2mm(配用5N6窄脉冲探头)
On the minimum detection range: < 1.2mm ( with 5N6 narrow pulse probe )
★远场分辨率:≥30dB(配用2.5P20-D探头)
In the far field resolution: = 30dB ( with 2.5P20-D probe )
★脉冲移位范围(钢纵波):0~400mm(扫描量程5、10、50mm),0~800mm(扫描量程250、1000mm)
Of pulse shift range ( steel longitudinal ) : 0 ~ 400mm ( scanning range 5, 10, 50mm ), 0 800mm ( scanning range 250, 1000mm )
★灵敏度余量:≥46dB(2.5P20-D直探头发现200mm-ф2平底孔)
In: sensitivity = 46dB ( 2.5P20-D straight probe found that 200mm - 2 flat-bottomed hole )
★重 量:主机5.5KG,带电池7.5KG
Of heavy weight: the host 5.5KG, 7.5KG with battery
★体积(长×宽×高):355mm×254mm×140mm
In volume ( length * width * height ): 355mm * 254MM * 140mm