| 测量原理 | 热式 |
| 主要特点 | 测量纯气体及混合气体的热式质量流量计
|
| 特点 | 快速设定,动态温度补偿,20种可选气体,可编程混合气体,现场标定,外部压力输入,确认,HistoROM S-DAT, HistoROM T-DAT,2个累加器
|
| Transmitter features | Flexible device configuration to suit the application - integrated “Gas Engine” functionality. For demanding applications - user-definable gas mixtures, high repeatability and accuracy. Automatic recovery of data for servicing. Device in compact or remote version. 4-20 mA HART, PROFIBUS PA/DP, Modbus RS485, FF.
|
| 直径 | "DN 15...100,1/2"...4"
|
| Wetted materials | Transducer: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) Process connections: 1.4404 (316L/316)
Sensor body: DN 15 to 25 (1/2"" to 1""): CF3M-A351 DN 40 to 100 (1-1/2"" to 4""): 1.4404 (316/316L) Bushing: PEEK GF30, PVDF O-ring seals: EPDM, Kalrez 6375, Viton FKM
|
| Measured variables | Mass flow, temperature, volume flow, energy flow
|
| 测量误差 | 读数值的± 1.5%...满量程的20%,,满量程的± 0.3%... 1%
|
| 量程 | 气体状态及过程状态,如0.5 ...3750 kg/h (1 bar及24℃下的空气)
|
| 压力范围 | PN 40
|
| 过程温度 | -40 ... +100℃
|
| 环境温度 | -20 °C to +60 °C (-4 °F to +140 °F) Optional: -40 °C to +60 °C (-40 °F to +140 °F)
|
| Transmitter housing material | Transmitter housing: Compact: powder coated die-cast aluminium Wall-mount: powder coated die-cast aluminium Remote field: powder coated die-cast aluminium Connection housing (remote version): powder coated die-cast aluminium
|
| 电子插件的防护 | IP 67 NEMA 4x
|
| 显示/操作 | 两行LCD背光显示,16字符的显示菜单,按键操作
|
| 输出 | 0/4...20mA 脉冲/频率 (1KHz,有源/无源),2个继电器,状态
|
| 输入 | 状态、0/4...20mA
|
| 通信 | HART,PROFIBUS DP,MODBUS RS485
|
| Power supply | 85 to 260 VAC, 45 to 65 Hz 20 to 55 VAC, 45 to 65 Hz 16 to 62 VDC
|
| 防爆认证 | ATEX、FM、CSA
|
| Product safety | CE, C-tick, EAC marking
|
| Pressure approvals and certificates | PED, CRN
|
| Hygienic approvals and certificates | Oxygen service (certified acc. To BS IEC 60877) |