Endress+Hauser e+h高压型涡…

Endress+Hauser e+h高压型涡街流量计O200
产品简介
详细介绍
  • 参考报价:暂无 产地:江苏 品牌:恩德斯豪斯 型号:O200 添加时间:2017/7/27 15:18:51

Endress+Hauser e+h高压型涡街流量计O200特征和规格

测量原理涡街
主要特点The flowmeter with a high pressure sensor, available as compact or remote version. Integrated temperature measurement up to PN 160 (Class 600). The specialist for applications with very high process pressure.
特点Highest mechanical integrity for flow measurement – special measuring tube material. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Process pressure up to PN 250 (Class 1500). DSC sensor made of Titanium (PN > 160 bar/Cl.600).
Transmitter featuresConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust two‐chamber housing.
直径DN 15 to 150 (? to 6")
Wetted materialsMeasuring tube: 1.4408 (CF3M); 1.4571 similar to 316Ti DSC sensor: UNS N07718 similar to Alloy 718, 2.4668; Titanium grade 5 similar to 3.7165
Connection: 1.4408 (CF3M); 1.4571 similar to F316 Ti; F316/F316L similar to 1.4404
Measured variablesVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
测量误差Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %
量程Liquid: 0.16 to 545 m3/h (0.09 to 321 ft3/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 7262 m3/h (1.18 to 4274 ft3/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
压力范围PN 250, Class 1500, 40K
过程温度PN 63 to 160, Class 600: –200 to +400 °C (–328 to +752 °F)
PN 250, Class 900 to 1 500: –50 to +400 °C (–58 to +752 °F)
环境温度Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing materialSensor connection housing: AlSi10Mg ,coated; 1.4408 (CF3M)
Transmitter housing materialAlSi10Mg, coated; 1.4404 (316L)
电子插件的防护Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure
显示/操作4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
输出4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
输入4‐20 mA (passive)
通信HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
防爆认证ATEX, IECEx, cCSAus, TIIS
Other approvals and certificates
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TüV attestation)
Pressure approvals and certificatesPED, CRN, AD 2000
Material certificates3.1 material 
NACE MR0175/MR0103, PMI (on request); only Class 900/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)


单位名称:南京仪信自动化工程有限公司