Endress+Hauser e+h缩颈型涡…

Endress+Hauser e+h缩颈型涡街流量计R200
产品简介
详细介绍
  • 参考报价:暂无 产地:江苏 品牌:恩德斯豪斯 型号:R200 添加时间:2017/7/27 15:26:03

Endress+Hauser  e+h缩颈型涡街流量计R200特征和规格

测量原理涡街
主要特点The flowmeter with the same accuracy despite line size reduction, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. Dedicated for applications with very low or reduced flow.
特点Cost and time saving – no pipework modifications needed for line size reduction. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").
Transmitter featuresConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust two‐chamber housing.
直径DN 25 to 250 (1 to 10")
Wetted materialsMeasuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)
Connection: 1.4404 (F316/F316L)
Measured variablesVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
测量误差Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %
量程Liquid: 0.26 to 545 m3/h (0.15 to 321 ft3/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 3.6 to 7262 m3/h (2.12 to 4274 ft3/min
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
压力范围PN 40, Class 300, 20K
过程温度Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
环境温度Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing materialSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing materialAlSi10Mg, coated; 1.4404 (316L)
电子插件的防护Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure
显示/操作4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
输出4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
输入4‐20 mA (passive)
通信HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
防爆认证ATEX, IECEx, cCSAus, TIIS
Other approvals and certificates
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificatesPED, CRN, AD 2000
Material certificates3.1 material 
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)