Endress+Hauser  e+h超声波流量计Prosonic Flow B 200沼气行业专用特征和规格

测量原理超声波
主要特点The device for accurate, reliable biogas measurement with loop‐powered technology. Integrated real‐time methane fraction measurement. Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.
特点Optimized for low pressure gas – specialized sensor design. No additional pressure loss – full bore design. Process transparency – diagnostic capability. Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F).
Transmitter featuresConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop‐powered technology. Robust dual-compartment housing.
直径Single‐path version: DN 50 (2"), DN 80 (3")
Two‐path version: DN 100 to 200 (4 to 8")
Wetted materialsSensor: 1.4404/1.4435 (316L)
Transducer: HNBR 
Temperature sensor (option): AFM 34
Measured variablesVolume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature
测量误差Volume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
量程Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
压力范围11 bar a (159 psi a)
过程温度0 to +80 °C (+32 to +176 °F)
环境温度Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Transmitter housing materialAlSi10Mg, coated; 1.4404 (316L)
电子插件的防护IP66/67, type 4X enclosure
显示/操作4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
输出4‐20 mA HART (passive)
4‐20 mA (passive) 
Pulse/frequency/switch output (passive)
输入Current input 4‐20 mA (passive)
通信HART
Power supplyDC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output)
防爆认证ATEX, IECEx, cCSAus, NEPSI, INMETRO, TIIS
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificatesPED
Material certificates3.1 material (wetted parts)