| 测量原理 | 导波雷达 |
| 特点/应用 | Premium device Multiparameter (capacitance and guided radar) Rod probe, Rope probe, Coaxial probe Integrated data memory, Factory precalibrated, Reliable measuring: for interface with emulsion, in case of moved surface + foam, for changing medias.
|
| Interface measurement | Interfaces liquid / liquid also with emulsion layers; Simultaneous measurement of interface and overall level
|
| 电源/通信 | 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART)
|
| 测量精度 | Rod probe : +/- 2 mm (0.08 in) Rope probe: +/- 2 mm (0.08 in) Coaxial probe: +/- 2 mm (0.08 in)
|
| 环境温度 | -40...+80 °C (-40...+176 °F)
|
| 过程温度 | –50...+200 °C (–58...+392 °F)
|
| 过程绝压/最大过压界限 | Vakuum...40 bar (Vacuum...580 psi)
|
| 接触介质部件 | Rod probe: 304, 316L, PTFE, PFA Rope probe: 304, 316, 316L, PTFE, PFA Coaxial probe: 304, 316L, PTFE, PFA
|
| 过程连接 | Flange: ASME 1 1/2"...6", DN50...DN150, JIS 10K
|
| 传感器长度 | Rod probe: 4 m (13 ft) Rope probe: 10 m (33 ft) Coaxial probe: 6 m (20 ft)
|
| 最大测量距离 | Rod: 4 m (13 ft) Min DK >1.4 Rope: 10 m (33 ft) Min DK >1.4 Coaxial: 6 m (20 ft) Min DK >1.4
|
| 输出 | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
| 证书和认证 | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC
|
| Safety approvals | SIL
|
| Design approvals | EN 10204-3.1 NACE MR0175, MR0103 ASME B31.1, B31.3 AD2000
|
| Marine approval | GL/ ABS/ LR/ BV/ DNV
|
| 可选项 | Sensor remote with 3 m/9 ft cable |