测量原理 | 差压 |
特点 | Digital transmitter with metallic measuring diaphragms Compact size Modular transmitter Long-term stability
|
电源/通信 | 4...20mA HART 11,5...45V DC (Non Ex): Ex ia: 11,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex)
|
测量精度 | 0,1% "PLATINUM" 0,075%
|
长期稳定性 | 0,05% of URL/year 0,125% of URL/5 years
|
过程温度 | -40°C...85°C (-40°F...185°F)
|
环境温度 | -40°C...85°C (-40°F...185°F)
|
量程 | 10mbar...40bar (0.15...580psi)
|
Smallest calibratable span | 10 mbar (0.145 psi) rel./ abs.
|
开关比 | 20:1
|
最大过压极限 | on one side: 160 bar (2300 psi)
|
过程连接 | 1/4-18 NPT
|
Material process membrane | 316L, AlloyC,
|
Material gasket | Viton, PTFE, EPDM, NBR
|
Fill fluid | Silicone oil, Inert oil,
|
Material housing | Die-cast aluminum
|
输出 | 4...20mA HART PROFIBUS PA FOUNDATION Fieldbus
|
证书和认证 | ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
|
Safety approvals | SIL
|
Design approvals | NACE MR0175 EN10204-3.1 |