产品介绍
MS-13X分子筛柱应用在岛津-安捷伦-赛默飞-瓦里安-PE-布鲁克
MS-13X分子筛柱应用在岛津-安捷伦-赛默飞-瓦里安-PE-布鲁克 详细信息:
催化裂化气体组成测定是炼油厂中重要的分析项目之一,其组成除含有C1~C5等轻烃组分外,还含有H2、O2、N2、CO、CO2等永jiu性气体。
浩瀚色谱(山东)应用技术开发有限公司,,采用MS-13X分子筛填充柱测定裂解气中氢,氧气、氮气、甲烷、一氧化碳缩短了分析时间,操作方便,方法的重复性好,准确度高,值得推广应用。
名称:岛津MS13X填充柱
规格:3.2mm*2.1mm*3m,80-100Mesh
zui高使用温度:320°C
分离:氢,氧,氮,一氧化碳,甲烷
适用于:岛津GC-7A,GC-7C,GC-14C,GC-2010,GC-2014,GC-2030
应用实例:
1.空气中氧,氮的分离
2.非甲烷总烃中用作甲烷柱
3.天然气中氢,氧,氮的分离
4.炼厂气,焦炉煤气,半水煤气,裂解气中永jiu气体的分离
5.变压器油溶解气体中氢,氧,氮,一氧化碳,甲烷的测定
6.高纯气体中氢,氧,氮,一氧化碳,甲烷的分离
7.甲醇制氢中氢,氧,氮,一氧化碳,甲烷的测定
适用于:
安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890
岛津GC-14C,GC-2010,GC-2014,GC-2030
赛默飞1310,1300,1610,1600
瓦里安3800系列
布鲁克PE580,590,680,690
磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓
MS-13X分子筛柱应用在岛津-安捷伦-赛默飞-瓦里安-PE-布鲁克 测试谱图:






Application of MS-13X molecular sieve column in Shimadzu Agilent Thermo Fisher Varian PE Brooke
MS-13X molecular sieve column application in Shimadzu Agilent Thermo Fisher Varian PE Bruker detailed information:
The determination of gas composition in catalytic cracking is one of the important analysis items in refineries. In addition to light hydrocarbon components such as C1 to C5, its composition also contains permanent gases such as H2, O2, N2, CO, CO2, etc.
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses MS-13X molecular sieve packed column to determine hydrogen, oxygen, nitrogen, methane, and carbon monoxide in cracking gas, which shortens the analysis time, is easy to operate, has good repeatability and high accuracy, and is worthy of promotion and application.
Name: Shimadzu MS13X filling column
Specification: 3.2mm * 2.1mm * 3m, 80-100Mesh
Maximum operating temperature: 320 ° C
Separation: hydrogen, oxygen, nitrogen, carbon monoxide, methane
Applicable to: Shimadzu GC-7A, GC-7C,GC-14C,GC-2010,GC-2014,GC-2030
Application example:
1. Separation of oxygen and nitrogen in the air
2. Used as a methane column in non methane total hydrocarbons
3. Separation of hydrogen, oxygen, and nitrogen in natural gas
4. Separation of Yongjiu gas from refinery gas, coke oven gas, semi water gas, and cracking gas
5. Determination of hydrogen, oxygen, nitrogen, carbon monoxide, and methane in dissolved gases of transformer oil
6. Separation of hydrogen, oxygen, nitrogen, carbon monoxide, and methane in high-purity gases
7. Determination of hydrogen, oxygen, nitrogen, carbon monoxide, and methane in methanol hydrogen production
Applicable to:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010,GC-2014,GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao
MS-13X molecular sieve column application in Shimadzu Agilent Thermo Fisher Varian PE Brooke test spectrum: