产品介绍
产品概述
等张传感器用于进行极小和极快的肌纤维的实验,这些极小的并快速收缩的肌纤维能够被100-200毫克以下的张力所牵拉,以至于能够测得最小的力和位移变化。
产品参数
输出电压: | 300μV 每毫米(杠杆头位移) | | 杠杆臂: | 6 cm |
线性度: | ± 2% to ± 15 ° 旋转角度 | | 起步转矩: | 小于0.1 gcm |
激发电压: | 6 ÷ 15 V | | 感性矩: | 35 gcm2 |
激发电流: | 20 mA (constant in the range 6 ÷ 15 V) | | 尺寸: | 16.5 x 5.5 x 11 cm |
工作范围: | ± 15° about the centre (zero) | | 净重: | 0.35 Kg |
杠杆臂长: | 10 cm | | 毛重: | 1.60 Kg |
产品特性
特征 | 优点 |
霍尔效应传感器 | 测量等张情况下的位移 |
钨合金平衡物 | 极速反应用于检测快速收缩 |
连接器有多种选择 | 能够用任何的数据采集系统采集数据 |
产品应用
- O. E. Kiroglu alia: “EThe effects of thiol modulators on nitrergic nerve- and S-nitrosothiols-induced relaxation in duodenum” J. of Basic and Clinical Physiol. & Pharmacol. 0 (0): 1-8, 2013
- M. Bucci et alia: “Cross-talk between toll-like receptor 4 (TLR4) and proteinase-activated receptor 2 (PAR2) is involved in vascular function” Br. J. Pharmacol. 168 (2): 411-420, 2013
- C. Jelen et alia: “Bone scaffolds with homogeneous and discrete gradient mechanical properties” Materials Science & Engineering: C 33 (1): 28-36, 2013
- M. Volta et alia: “Pharmacological profile and antiparkinsonian properties of the novel nociceptin/orphanin FQ receptor antagonist 1-[1-cyclooctylmethyl-5-(1-hydroxy-1-methyl-ethyl)-1,2,3,6-tetrahydropyridin-4-yl]-3-ethyl-1,3-dihydro-benzoimidazol-2-one (GF-4)” Peptides 31:1194–1204, 2010
- P.U. Ertug: “Protective effect of quercetin, a polyphenolic compound, on mouse corpus cavernosum“ Fundamental & Clinical Pharmacology 24: 223–232, 2010
- O. Desire et alia: “Antispasmodic and antioxidant activities of fractions and bioactive constituent davidigenin isolated from Mascarenhasia arborescens” J. Ethnopharmacology. J. Pharmacol. Accepted: May 2010, 2004
- D. Currò et alia: “EVoltage-gated calcium channels involved in the inhibitory motor responses and asoactive intestinal polypeptide release in the rat gastric fundus” Eur. J. Pharmacol. 628: 207-213, 2010
- C. Belloli et alia: “Adrenergic Regulation of Vascular Smooth Muscle Tone in Calf Digital Artery” J. Vet. Pharmacol. Therap. 27:4: 247-254, 2004
- F. Carpi et alia: “Electromechanical Characterisation of Dielectric Elastomer Planar Actuators: Comparative Evaluation of Different Electrode materials and Different Counterloads ” Sensors and Actuators. 107: 85-95, 2003
- P. Tucci et alia: “Cyclo-Oxygenase- and Capsaicin-Sensitive Afferent Fibres Affect Beta-Adrenoceptor-Evoked Response in the Rat Urinary Bladder” Pharmacology 64: 57-62, 2002
- P.C. Moser et alia: “SL65.0155, A Novel 5-Hydroxytryptamine4 Receptor Partial Agonist with Potent Cognition-Enhancing Properties” J. Pharmacol. Exper. Therap. 302:2: 731-741, 2002
- P. Tucci et alia: “Effects of Natural Tachykinins on Ovine Lower Urinary Tract Smooth Muscle” J. Autonomic Pharmacol. 21:2: 79-84, 2001
- C.M.Q. Jesus-Morais et alia: “Yangambin, a Lignan Obtained from Ocotea duckei, Differentiates Putative PAF Receptor Subtypes in the Gastrointestinal Tract of Rats” Planta Med. 66:4: 211-216, 2000