Tail Flick Test Analgesia Meter for Mice and Rats
The IITC Tail Flick Test apparatus meter measures latency and/or temperature threshold when detecting properties of narcotic and strong non-narcotic drugs on mice and rats. A built-in Timer is automatically stopped when the animals’ tail flicks out of the beam of light, test result will be displayed on readout for viewing.
An overhead halogen light source is in a constant “ON” (idle state). A pre-focused heat source supplies an area of 4X6mm stimulation to the tail. A built-in sensor in the tail groove detects the tail flick of the animal. The tail groove is a non-metallic material to avoid unnecessary conditioning of your animals; unlike other systems. If the animal does not flick their tail within the pre programmed cut-off time; the heat source shuts off automatically; avoiding tissue damage. Built-in timer displays the reaction time in 0.01 second increments. Control of system can be from either the front panel or supplied footswitch: Start, Stop and Reset of tests.
TAIL TEMPERATURE OPTION (T)

Measurement of tail temperature at all times.
Trigger temperature is automatic at start of every test. Warms tail to preset temperature (set by user) and then tests start, allowing all tail temperatures to be identical.
This optional feature allows automatic preheating of the tail up to 75 degrees c., ensuring all experiment protocols to be precisely controlled and repeated. Once a preset temperature is reached, the test and timer start automatically. Once the animal reacts via tail flick the timer and heat source stop and test results are displayed. Readout will now show in repeatable sequence, start , end temperatures and test time. This unique feature stores the set temperature unless otherwise changed; eliminating temperature variations from test to test. We recommend that animals be restrained with one of the IITC restrainers.
This unit solves the problem associated with “tail temperature prior to and at the end of testing.” See article: KJELL HOLE AND ARNE TJOLSEN: The Tail-Flick Formalin Test in Rodents: Changes in Skin Temperature as a Confounding Factor. Pain 53 (1993) pages. 247-254 Elsevier).
IITC痛觉测试系统
电子Von Frey测痛仪 Electronic von Frey Anesthesiometer
 | 电子Von Frey测痛仪用来评估机械痛(阈值), “Supertips ” (软头) 用来检测所有的感官阈测试。电子Von Frey测痛仪提供的探针有90g、800 g和1000g三种规格。探针的类型视实验对象而定。 |
冷热板痛觉测试仪 Hot Cold Plate Analgesia Meter for Mice and Rats
| 传统的热板测试只能测试动物疼痛反应时间,同时由于冷却时间长不能用于温度升高测试和重复测试。IITC采用微处理器控制温度升高和降低,用于测量动物对镇痛药物的疼痛反应极限,扩大了镇痛药物研究的范围。 l 冷热痛觉测试 l 快速升温和降温,每分钟可升降10℃,适合重复测试 温度稳定性为0.1℃ l 温度范围从0到70℃ l 时间精度为0.01秒 l 标准计算机打印口,输出 RS-232输出 |
热板痛觉测试仪 Hot Plate Analgesia Test Meter Mice and Rats
 | 热板疼痛测试仪通过测试大鼠和小鼠的疼痛反应时间,进行快速精确地筛选麻醉型镇痛药物。 l 可测量大鼠和小鼠 温度步进量0.1摄氏度 l 控制保持精度+/- 0.1摄氏度 l 时间精度为0.01秒 l 温度范围从室温到75摄氏度 |
IITC热辐射测痛仪 Plantar Test Apparatus
| 热刺激痛觉实验用于测试镇痛药物影响无束缚大鼠对外部热刺激的反应时间,使用时先通过从爪下面的测试头发出导向光将光源移到动物爪底,通过反光镜确定位置,避免频繁弯腰和低头,方便操作,启动加热光束照射到动物爪底进行实验。 l 精确数字控制, 时间精确度为0.01秒 l 光束强度可调节,步进量1% l 加热玻璃可选配 l 测试头具有反光镜辅助观察 |
鼠爪压力疼痛测试仪 Randall Selitto Paw Pressure Test Apparatus Mice and Rats
 | Randall&Selitto测试,通过逐步提高作用于动物爪子上的机械压力,逼近动物的疼痛阈限,测量并记录动物产生逃避反应时的瞬间最大压力,以测定动物机械钝痛的痛觉阈限。常用于辨别左右爪不同的痛觉反应,多涉及脊髓神经过程,人工辨别动物缩腿反应,并用踏板控制马达的起止。 l 适用于大鼠和小鼠 l 精确度为0.1克,最大压力400克 l 数字显示功能 l 配置脚踏控制器 |
双足平衡法测痛仪 Incapacitance Meter Tester Mice, Rats and Birds
 | 双足平衡法测痛仪用于对大鼠或小鼠后肢的痛觉和发炎测试评估,克服了其它测试方式可能引起的动物紧张或主观性问题,该技术采用双通道重量平均法,可以同时对一只动物进行控制和测试,可选购大鼠或小鼠两种型号。 双足平衡测试法(Incapacitance Analgesia Meter )可以自动并且是可重复的评估止痛效果。 l 精确数字控制精度为0.1克 自动检测反应 l 配置脚踏控制器 |
疼痛甩尾测试仪 Tail Flick Test Analgesia Meter for Mice and Rats
 | 疼痛甩尾测试仪用于测试动物疼痛反应时间和动物对镇痛药物的疼痛反应极限.实验过程中,检测到动物尾部甩动后内置的计时器自动停止计时. l 实时尾部温度/触发可选 l 触发温度设置功能 l 精确数字控制,时间精确度为0.01秒 l 自动切断保护功能 l 光束强度可调节,步进量1% l 自动检测活动反应 |
鼠爪肿胀测定仪 Plethysmometer (Paw Volume) Meter  | IITC爪体积测量仪用来衡量消炎药的有效性。使用时,爪子浸入测试槽中, 由于浸泡水的压力发生了变化。压力的变化会被校准,并显示在特殊的电子监视器上。这种检测形式可以消除由于重复浸入发生导电性的改变而产生的改变,这种情况在类似的其他仪器上发现过。 测试结果直接显示在LCD上 大鼠精确到0.01毫升、小鼠精确到0.001毫升 |