10155 |
SIGMA 2-16P实验室通用离心机 |
11122(for sigma2-16P) |
Swing-out rotor for microtiter plates, incl. 1 set carriers no. 13222, max. height of plates 56 mm |
11123(for sigma2-16P) |
Swing-out rotor for microtiter plates, incl. 1 set carriers no. 13223, max. height of plates 50 mm |
11190(for sigma2-16P) |
Swing-out rotor 4 x 100 ml complete, no. 11192, incl. 2 sets bucket no. 13097 and 4 glass tubes 100 ml no. 15100 |
11191(for sigma2-16P) |
Swing-out rotor 16 x 15 ml complete, no. 11192, incl. 2 sets carriers no. 13012 and 16 PS-tubes 15 ml no. 15020 |
11192(for sigma2-16P) |
Swing-out rotor, 4 place, for buckets no. 13009, 13012, 13041, 13042, 13097, 13150, 13152; 13041 and 13152 for rotors from the year 2003 onwards only |
11409(for sigma2-16P) |
Microhematocritrotor suitable for 24 capillary tubes Ø 1.5 x 75 mm, 50 µl no. 15001, incl. reader no. 17029, usable with reader 17002 |
12071(for sigma2-16P) |
Angle rotor for 12 x 15 ml culture, e.g. no. 15115 and 6 x 50 ml culture e.g. no. 15151 |
12072(for sigma2-16P) |
Angle rotor 20 x 15 ml complete, incl. 10 sets buckets no. 13011, for tubes Ø 17 x up to 120 mm, e.g. no. 15015, 15020, 15023, 15024, Monovettes and culture tubes 15 ml no. 15115 |
12073(for sigma2-16P) |
Angle rotor 30 x 15 ml complete, incl. 15 sets buckets no. 13011, for tubes Ø 17 x up to 120 mm, e.g. no. 15015, 15020, 15023, 15024, Monovettes and culture tubes 15 ml no. 15115 |
12107(for sigma2-16P) |
Angle rotor, for 12 PCR-strips with 8 tubes 0.2 ml e.g. no. 15042, incl. hermetic aluminium lid no. 17870 |
12133(for sigma2-16P) |
Angle rotor 30 x 1.5|2.2 ml, for e.g. reaction vials no. 15008, 15040, incl. hermetic aluminium lid no. 17863 |
12139(for sigma2-16P) |
Angle rotor 6 x 30 ml, for tubes no. 15029, 15030, 15032, incl. hermetic aluminium lid no. 17851 |
12141(for sigma2-16P) |
Angle rotor 10 x 10 ml, for tubes no. 15000, 15010, 15039, incl. hermetic aluminium lid no. 17850 |
12148(for sigma2-16P) |
Angle rotor 24 x 1.5|2.2 ml, for e.g. reaction vials no. 15008, 15040, incl. hermetic aluminium lid no. 17864 |
12151(for sigma2-16P) |
Angle rotor for 6 x 50 ml culture, e.g. no. 15151, incl. hermetic aluminium lid no. 17862 |
13222(for sigma2-16P) |
Bucket for microtiter plates, 1 set = 2 pcs. |
13223(for sigma2-16P) |
Bucket for microtiter plates, 1 set = 2 pcs. |
13012(for sigma2-16P) |
Multiple carrier for 4 tubes 5-15 ml, incl. rubber cushion no. 16015, max. Ø 17|19 x 90-105 e.g no. 15015, 15020, 15023, 15024, Monovettes 9-10 ml, 1 set = 2 pcs.mm, |
13009(for sigma2-16P) |
Multiple carrier for 5 tubes 5 ml, round and flat bottom, incl. rubber cushion no. 16005, max. Ø 12. 8|16.5 x 65-85 mm, e.g. no. RIA tube 15060, vacutainer, hemolyse tubes, 1 set = 2 pcs. |
13041(for sigma2-16P) |
Round bucket for round carriers Ø 43.5 mm, no. 14029, 14030, 14031, 14032, 14033, 14034, 14035, incl. polysulfone screw cap no. 17130, max. tube length 110 mm, 1 set = 2 pcs. |
13042(for sigma2-16P) |
Multiple carrier for 6 tubes 5 to 15 ml, max. Ø 17|19 x 90-105 mm, e.g no. 15000, 15010, 15015, 15020, 15022, 15023, 15024, 15039 Monovettes 9-10 ml, from 2003 onwards only Vacutainer, incl. rubber c |
13150(for sigma2-16P) |
Bucket incl. polysulfone screw cap no. 17151 for 1 culture tube 50 ml, e.g. no. 15151, 1 set = 2 pcs. |
13152(for sigma2-16P) |
Multiple carrier for 2 culture tubes 15 ml, e.g. no. 15115, 1 set = 2 pcs. |
13011(for sigma2-16P) |
Spare Nylon bucket for 1 tube 15 ml e.g. no. 15015, 15020, 15023, 15024, 1 set = 2 pcs. |