产品介绍
华仪7440安规综合测试仪
MODEL |
7450
|
7451
|
7452
|
AC WITHSTAND VOLTAGE | |||
Output Rating | 5KVAC/100mA Constant 500VA | ||
Range
|
Resolution
|
Accuracy
|
|
Output Voltage, ACV |
0 - 5000
|
1
|
±(2% of setting + 5V)
|
Output Frequency | 50Hz/60Hz ±100ppm, User Selection | ||
Output Waveform | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 | ||
Output Regulation | ± (1% of output + 5V), From no load to full load | ||
SETTINGS | |||
Hi-Limit AC Current, mA |
0 - 99.99
|
0.01
|
±(2% of setting + 3counts)
|
Lo-Limit AC Current, mA |
0 - 9.999
|
0.001
|
±(2% of setting + 3counts)
|
Ramp Time, second |
0.1 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
Dwell Time, second |
0, 0.3 - 999.9
(0=continuous) |
0.1
|
|
Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | ||
AC Current Offset, mA | 0 - 2.000 or Auto Set | ||
DC WITHSTAND VOLTAGE (7451,7452 ONLY) | |||
Output Rating | 6KVDC/9999µA | ||
Output Voltage, DCV | 0 - 6000 | 1 | ±(2% of setting + 5V) |
Output Ripple | <5%(6KV/9999µA at Resistive Load) | ||
SETTINGS | |||
Hi-Limit DC Current, µA |
0 - 9999
|
1
|
±(2% of setting + 3counts)
|
Lo-Limit DC Current, µA |
0 - 999.9
|
0.1
|
±(2% of setting + 3counts)
|
Ramp Time, second |
0.1 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
Dwell Time, second |
0, 0.4 - 999.9
(0=continuous) |
0.1
|
|
Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | ||
DC Current Offset, µA | 0 - 200.0 or Auto Set | ||
Ramp High Current | ON/OFF, User Selection | ||
Charge - Low Current, µA | 0 - 350.0 or Auto Set | ||
Discharge Time | ≦ 200 msec | ||
INSULATION RESISTANCE | |||
Output Rating | 1KVDC/9999MΩ | ||
Output Voltage, DCV |
100 - 1000
|
1
|
±(2% of setting + 3V)
|
Hi-Limit Resistance, MΩ |
0, 1 - 9999 (0=OFF)
|
1
|
±(2% of setting+2counts)at 500-1000VDC, 1 -1000 MΩ
±(8% of setting+2counts)at 500-1000VDC, 1000 -9999 MΩ ±(8% of setting+2counts)at 100-500VDC, 1 -1000 MΩ |
Lo-Limit Resistance, MΩ |
1 - 9999
|
1
|
|
Delay Time, second |
0, 0.5 - 999.9
(0=continuous) |
0.1
|
±(0.1% + 0.05sec)
|
Charge - Low Current, ?A |
0 - 3.500 or Auto Set
|
||
GROUND BOND (7452 ONLY) | |||
Output Rating | 30A/600mΩ, 8V | ||
Output AC Current, A |
3.00 - 30.00
|
0.01
|
± (2% of setting +2 counts)
|
Output AC Voltage, V |
3.00 - 8.00
|
0.01
|
± (2% of setting +3 counts)
|
Output Frequency | 50Hz/60Hz ±100ppm, User Selection | ||
SETTINGS | |||
Hi-Limit Resistance, mΩ |
0 - 150 (3 - 30A)
|
1
|
± (2% of setting +2 counts)
|
Lo-Limit Resistance, mΩ |
0 - 600 (3 - 10A)
|
||
Lead Resistance Offset, mΩ |
0 -200
|
1
|
± (2% of setting +2 counts)
|
Dwell Time, second |
0, 0.5 - 999.9 sec (0 = continuous)
|
0.1
|
±(0.1% + 0.05sec)
|
MEASUREMENT | |||
AC/DC Voltage, KV |
0 - 6.00
|
0.01
|
±(1.5% of reading + 1count)
|
DC Voltage, V (IR) |
100 - 1000
|
1
|
±(1.5% of reading + 3count)
|
AC Current Range, mA |
0-3.500
|
0.001
|
±(2% of reading + 3counts)
|
3.00-99.99
|
0.01
|
±(2% of reading + 6counts)
|
|
DC Current Range, µA |
0-350.0
|
0.1
|
± (2% of reading + 3counts)
|
300 - 3500
|
1
|
± (2% of reading + 2counts)
|
|
3000-9999
|
10
|
± (2% of reading + 6counts)
|
|
AC Current, A (GB) |
0 - 35.00
|
0.01
|
±(2% of reading+2counts)
|
Resistance, , MΩ(IR) |
1 - 9999
(Auto Range) |
—
|
±(2% of reading+2counts)at 500-1000VDC, 1 -1000 MΩ |
±(8% of reading+2counts)at 500-1000VDC, 1000 -9999 MΩ | |||
±(8% of reading+2counts)at 100-500VDC, 1 -1000 MΩ | |||
Resistance, , mΩ(GB) |
0 - 600
|
1
|
±(2% of reading+2counts)
|
GENERAL | |||
Input Voltage AC | 100/115/200/230Vac±15%, 50/60Hz ± 5%, Fuse 15A | ||
PLC Remote Control | Input : Test , Reset , Memory1.2.3 | ||
Output : Pass , Fail , Processing | |||
Memory | 50 memories, 8 steps/memory | ||
Display | 20×2 LCD with back light | ||
Key Lock | To prevent unauthorized alteration of the test Parameters | ||
Calibration | Build-in software and external calibrated meters | ||
Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. | ||
Rear Panel Output |
YES
|
YES
|
YES
|
Built-in Scanner |
-
|
-
|
-
|
External Scanner |
-
|
YES
|
YES
|
Smart GFI |
YES
|
YES
|
YES
|
Analog Meter |
YES
|
YES
|
YES
|
RS232 Interface |
-
|
Option
|
Option
|
GPIB Interface |
-
|
YES
|
YES
|
Printer Interface |
-
|
Option
|
Option
|
TUV-GS listed |
YES
|
-
|
YES
|
CE Compliance |
YES
|
-
|
YES
|
Environment |
0-40℃, 20-80%RH
|
||
Dimension (W×H×D) |
430×133×400 (mm)
|
430×133×400 (mm)
|
430×133×500 (mm)
|
Net Weight |
28Kg
|
28Kg
|
32Kg
|
STANDARD ACCESSORIES | |||
Power Cord(15A) |
×1
|
||
Fuses |
×2 (Including a spare contained in the fuse holder)
|
||
Hipot Test Lead ,1.5m(1101) |
×1
|
×1
|
×1
|
Hipot Return Lead ,1.8m(1102) |
×1
|
×1
|
-
|
Ground Bond Test Lead 30A ,1.5m(1103) |
-
|
-
|
×1
|
Ground Bond Return Lead 30A ,1.5m(1104) |
-
|
-
|
×1
|
*product specifications are subject to change without notice |
深圳市乐买宜电子有限公司是专业从事工业量测产品以及MRO(用于工厂维护、维修以及正常运转的仪器,工具,耗材等)的销售和服务的优质供应商。 我们用开放的胸怀,分享的精神…... 了解更多>>