产品介绍
华仪7440安规综合测试仪
| MODEL |
7450
|
7451
|
7452
|
| AC WITHSTAND VOLTAGE | |||
| Output Rating | 5KVAC/100mA Constant 500VA | ||
|
Range
|
Resolution
|
Accuracy
|
|
| Output Voltage, ACV |
0 - 5000
|
1
|
±(2% of setting + 5V)
|
| Output Frequency | 50Hz/60Hz ±100ppm, User Selection | ||
| Output Waveform | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 | ||
| Output Regulation | ± (1% of output + 5V), From no load to full load | ||
| SETTINGS | |||
| Hi-Limit AC Current, mA |
0 - 99.99
|
0.01
|
±(2% of setting + 3counts)
|
| Lo-Limit AC Current, mA |
0 - 9.999
|
0.001
|
±(2% of setting + 3counts)
|
| Ramp Time, second |
0.1 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
| Dwell Time, second |
0, 0.3 - 999.9
(0=continuous) |
0.1
|
|
| Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | ||
| AC Current Offset, mA | 0 - 2.000 or Auto Set | ||
| DC WITHSTAND VOLTAGE (7451,7452 ONLY) | |||
| Output Rating | 6KVDC/9999µA | ||
| Output Voltage, DCV | 0 - 6000 | 1 | ±(2% of setting + 5V) |
| Output Ripple | <5%(6KV/9999µA at Resistive Load) | ||
| SETTINGS | |||
| Hi-Limit DC Current, µA |
0 - 9999
|
1
|
±(2% of setting + 3counts)
|
| Lo-Limit DC Current, µA |
0 - 999.9
|
0.1
|
±(2% of setting + 3counts)
|
| Ramp Time, second |
0.1 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
| Dwell Time, second |
0, 0.4 - 999.9
(0=continuous) |
0.1
|
|
| Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | ||
| DC Current Offset, µA | 0 - 200.0 or Auto Set | ||
| Ramp High Current | ON/OFF, User Selection | ||
| Charge - Low Current, µA | 0 - 350.0 or Auto Set | ||
| Discharge Time | ≦ 200 msec | ||
| INSULATION RESISTANCE | |||
| Output Rating | 1KVDC/9999MΩ | ||
| Output Voltage, DCV |
100 - 1000
|
1
|
±(2% of setting + 3V)
|
| Hi-Limit Resistance, MΩ |
0, 1 - 9999 (0=OFF)
|
1
|
±(2% of setting+2counts)at 500-1000VDC, 1 -1000 MΩ
±(8% of setting+2counts)at 500-1000VDC, 1000 -9999 MΩ ±(8% of setting+2counts)at 100-500VDC, 1 -1000 MΩ |
| Lo-Limit Resistance, MΩ |
1 - 9999
|
1
|
|
| Delay Time, second |
0, 0.5 - 999.9
(0=continuous) |
0.1
|
±(0.1% + 0.05sec)
|
| Charge - Low Current, ?A |
0 - 3.500 or Auto Set
|
||
| GROUND BOND (7452 ONLY) | |||
| Output Rating | 30A/600mΩ, 8V | ||
| Output AC Current, A |
3.00 - 30.00
|
0.01
|
± (2% of setting +2 counts)
|
| Output AC Voltage, V |
3.00 - 8.00
|
0.01
|
± (2% of setting +3 counts)
|
| Output Frequency | 50Hz/60Hz ±100ppm, User Selection | ||
| SETTINGS | |||
| Hi-Limit Resistance, mΩ |
0 - 150 (3 - 30A)
|
1
|
± (2% of setting +2 counts)
|
| Lo-Limit Resistance, mΩ |
0 - 600 (3 - 10A)
|
||
| Lead Resistance Offset, mΩ |
0 -200
|
1
|
± (2% of setting +2 counts)
|
| Dwell Time, second |
0, 0.5 - 999.9 sec (0 = continuous)
|
0.1
|
±(0.1% + 0.05sec)
|
| MEASUREMENT | |||
| AC/DC Voltage, KV |
0 - 6.00
|
0.01
|
±(1.5% of reading + 1count)
|
| DC Voltage, V (IR) |
100 - 1000
|
1
|
±(1.5% of reading + 3count)
|
| AC Current Range, mA |
0-3.500
|
0.001
|
±(2% of reading + 3counts)
|
|
3.00-99.99
|
0.01
|
±(2% of reading + 6counts)
|
|
| DC Current Range, µA |
0-350.0
|
0.1
|
± (2% of reading + 3counts)
|
|
300 - 3500
|
1
|
± (2% of reading + 2counts)
|
|
|
3000-9999
|
10
|
± (2% of reading + 6counts)
|
|
| AC Current, A (GB) |
0 - 35.00
|
0.01
|
±(2% of reading+2counts)
|
| Resistance, , MΩ(IR) |
1 - 9999
(Auto Range) |
—
|
±(2% of reading+2counts)at 500-1000VDC, 1 -1000 MΩ |
| ±(8% of reading+2counts)at 500-1000VDC, 1000 -9999 MΩ | |||
| ±(8% of reading+2counts)at 100-500VDC, 1 -1000 MΩ | |||
| Resistance, , mΩ(GB) |
0 - 600
|
1
|
±(2% of reading+2counts)
|
| GENERAL | |||
| Input Voltage AC | 100/115/200/230Vac±15%, 50/60Hz ± 5%, Fuse 15A | ||
| PLC Remote Control | Input : Test , Reset , Memory1.2.3 | ||
| Output : Pass , Fail , Processing | |||
| Memory | 50 memories, 8 steps/memory | ||
| Display | 20×2 LCD with back light | ||
| Key Lock | To prevent unauthorized alteration of the test Parameters | ||
| Calibration | Build-in software and external calibrated meters | ||
| Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. | ||
| Rear Panel Output |
YES
|
YES
|
YES
|
| Built-in Scanner |
-
|
-
|
-
|
| External Scanner |
-
|
YES
|
YES
|
| Smart GFI |
YES
|
YES
|
YES
|
| Analog Meter |
YES
|
YES
|
YES
|
| RS232 Interface |
-
|
Option
|
Option
|
| GPIB Interface |
-
|
YES
|
YES
|
| Printer Interface |
-
|
Option
|
Option
|
| TUV-GS listed |
YES
|
-
|
YES
|
| CE Compliance |
YES
|
-
|
YES
|
| Environment |
0-40℃, 20-80%RH
|
||
| Dimension (W×H×D) |
430×133×400 (mm)
|
430×133×400 (mm)
|
430×133×500 (mm)
|
| Net Weight |
28Kg
|
28Kg
|
32Kg
|
| STANDARD ACCESSORIES | |||
| Power Cord(15A) |
×1
|
||
| Fuses |
×2 (Including a spare contained in the fuse holder)
|
||
| Hipot Test Lead ,1.5m(1101) |
×1
|
×1
|
×1
|
| Hipot Return Lead ,1.8m(1102) |
×1
|
×1
|
-
|
| Ground Bond Test Lead 30A ,1.5m(1103) |
-
|
-
|
×1
|
| Ground Bond Return Lead 30A ,1.5m(1104) |
-
|
-
|
×1
|
| *product specifications are subject to change without notice | |||
来宝会员深圳市乐买宜电子有限公司是专业从事工业量测产品以及MRO(用于工厂维护、维修以及正常运转的仪器,工具,耗材等)的销售和服务的优质供应商。 我们用开放的胸怀,分享的精神…... 了解更多>>