产品介绍
Active活性胰高糖素样肽 ELISA Kit
Catalog Number: KT-871
Storage:This test kit must be stored at 2 – 8°C upon receipt.
INTENDED USE
This high sensitive ELISA (enzyme-linked immunosorbent assay) kit is produced for the exclusively quantitative determination of bioactive glucagon-like peptide-1 (7-36) [GLP-1 (7-36)] level in plasma samples. The primary amino acid sequence of GLP-1 peptide is identical among mammalian species, i.e. rat, mouse, pig, human, etc. This kit is for research purpose only.
ASSAY PRINCIPLE
This ELISA is designed, developed and produced for the quantitative measurement of bioactive GLP-1 (7-36) in plasma sample. The assay utilizes the two-site “sandwich” technique with two selected GLP-1 (7-36) specific antibodies.
Assay standards, controls and test samples are directly added to wells of a microplate that is coated with streptavidin. Subsequently, a mixture of biotinylated GLP-1 (7-36) specific antibody and a horseradish peroxidate (HRP) conjugated GLP-1 (7-36) specific antibody is added to each well. After the first incubation period, a “sandwich” immunocomplex of “Streptavidin – Biotin-Antibody – GLP-1(7-36) – HRP conjugated antibody” is formed and attached to the wall of the plate. The unbound HRP conjugated antibody is removed in a subsequent washing step. For the detection of this immunocomplex, each well is then incubated with a substrate solution in a timed reaction and then measured in a spectrophotometric microplate reader. The enzymatic activity of the immunocomplex bound to GLP-1 (7-36) on the wall of the microtiter well is directly proportional to the amount of GLP-1 (7-36) in the sample.
REAGENTS: Preparation
1. Streptavidin Coated Microplate:96 wells
2. GLP-1 Tracer Antibody:1vial× 0.6 mL
3. GLP-1 (7-36) Capture Antibody:1vial× 0.6 mL
4. ELISA Wash Concentrate,30X:1 bottle× 20mL
5. ELISA HRP Substrate :1 bottle× 24mL
6. ELISA Stop Solution:1 bottle× 12mL
7. GLP-1 Standards:6 vials
8. GLP-1 Controls:2 vials
9. Tracer Antibody Diluent:1vials× 12mL
Short Assay Protocol:
- Add 100 μl/well of standards, control and patient sample
- Add 100 μl of Antibody Mixture
- Incubate 20 - 24 hour at 2-8°C, static
- Wash strips with diluted wash buffer
- Add 200 μl/well of TMB substrate
- Incubate 20 min at RT, static
- Add 50 μl stop solution
- Read strips at OD 450 nm/620 nm or 450 nm/650 nm
Frank Ou
Regional Sales Manager
Epitope Biotechnology Co.,Ltd.
599 Yazhong Rd.1-4F,jiaxing,zhejiang
PM: 13967333273
Tel: 0573-82809169
Fax: 0573-82809206
Email: zou@xjbiotech.com
http://www.xjbiotech.com