Capable of recording from neonatal mice (1.4 g) to aged rats (1 kg) Main Features 1. Two operation modes are available. NOTE:HR (Heart Rate), SBP (Systolic BP), MBP (Mean BP), DBP (Diastolic BP, calculated value) 2. Continuous Measurement Function 5. Sick animals can be measured. (e.g. animal with cardiac infarction) 6. Multi-channel system is no longer needed. Just prepare multiple restrainers, and measurement can be done one after the other. 7.Auto-Sequence Function 8. Time-Stamp Function 9. Hard Copy Function 10. An RS-232C interface is provided on the rear panel of the main unit. Using the optional DCS-2000 Data Collection Software (Windows Version) the data obtained can be exported to a personal computer and stored as a CSV file. 11. The animal holders are made of dark brown acryl, allowing BP measurement under relatively stress-free conditions. 12. Operation is very simple.
新生小鼠大鼠不需预热无创血压监测仪
[ 作者:佚名 | 来源:本站原创 | 点击数:157 | 更新时间:2010-11-10 ]
日本MuromachiKikai的大小鼠无创血压仪是目前世界上最好的大小鼠无创血压仪设备,
2 测量HR/SBP/MBP/DBP,可以显示在显示屏上
3 HR由10次脉搏决定
4 SBP初始值由加压至25毫米汞柱每秒。放气值大约4-5毫米汞柱每秒,SBP很准确
5 加压可以至400毫米汞柱每秒,SHRSP可以被测量
6 连续测量可达6次
7 动物管是由黑色棕丙烯醛基制作,动物在相当安静无干扰的环境下测量
8 PMB-1030预热测量腔来自于标准系统
9 串口设计连接数据输出打印,DCS-1030数据采集软件
10 A4纸大小,便携
11 操作简单
MK-2000ST is ideal for investigating the effects of drugs on animals. Once the animals are restrained properly, just press the START key and HR (Heart Rate), SBP (Systolic BP), MBP (Mean BP) and DBP (Diastolic BP, calculated value) will be automatically measured.
It photoplethysmographically measures pulsatile blood pressure of tail arteries. Pulses are stored into the computer memory and the peak levels of the pulses are plotted on the display. X-axis indicates cuff pressure, and Y-axis indicates amplitude of pulses. Using this method, the operator can decrease the risk of selecting artifacts and BP measurement is made more objective compared to the conventional digital display method.
SBP is initially estimated by inflating the cuff at approximately 25 mmHg/sec. During cuff deflation at about 4-5 mmHg/sec, SBP is determined precisely. SBP is defined as the point when the pulse reappears..
With Mode 1 HR (Heart Rate) and SBP (Systolic Blood Pressure) are measured. With Mode 2 HR, SBP, MBP (Mean Blood Pressure) and DBP (Diastolic Blood Pressure, calculated value) can be measured.
MODE1
HR
SBP
MODE2
HR
SBP
MBP
(DBP)
Continuous measurement can be performed up to ten (10) times. Further, continuous & rapid measurement can also be performed in order to shorten the measuring time.
3. Rapid Printout Function
Onscreen data including average (AV) and standard deviation (SD), are printed out in about one (1) second by the high-performance thermal printer. Data may also be deleted at the operator's discretion.
4. Colored mice such as C57BL/6, neonatal mice weighing 1.4 grams, hamsters (anaesthetized) and guinea pigs (non-anaesthetized), of which blood pressure was so far considered difficult to measure, can be measured.
Blood pressure of a tail artery of an animal can be monitored automatically at specified time intervals, which can be 1 - 99 minutes in length. At each interval, anywhere from 1-10 measurements can be made. This function invokes a series of procedures automatically--- measurement, printout of data and transfer to a PC.
The MK-2000ST precisely records the time of each BP measurement.
The screen on the display can be captured to the thermal printer using the PrtScreen key.
美国健康医疗仪器国际公司 于2000年策划,次年初创建于美国纽约,主要从事医学科研和临床治疗仪器的开发、生产和销售。同时进行心血管药物的基础研究、中成药的二次开发和…... 了解更多>>