产品介绍
DICKSON D182/D186非接触红外测温仪Infrared Thermometer
型号 | 温度范围 | 温度精度 | 尺寸 | 电池 |
D182 | -76 to 932F (-60 to 500C) | | 6.9 x 1.54 x 2.83in | 是 |
D186 | -67 to 536F (-55 to 280C) | +/- 1F from 32 to 150F | 6 x 1.5 x 3in | 是 |
DICKSON TM320/325/725温湿度数据记录仪
型号 | 温度范围 | 温度精度 | 湿度范围 | 湿度精度 | 远程探头 | 带数显 | 报警 |
TM320 | -4 to 158 F | +/- 2 % RH from 0 to 60 % RH | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH | | 是 | 是 |
TM325 | -40 to 158 F | +/- 1.8 F from -4 to 158 F | 0-95% RH non-condensing | +/- 3 % RH from 60 to 95 % RH | 是 | 是 | 是 |
TM725 | -40 to 158 F | +/- 0.8 F from 20 to 120 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH
+/- 3 % RH from 60 to 95 % RH | 是 | 是 | 是 |
DICKSON SM300/320/325/420/720/725温度数据记录仪
型号 | 网络连接 | 温度精度 | 温度范围 | 远程探头 |
SM300 | MP100 | 0.8F
0.5C | -4 to 158F
-20 to 70C | |
SM320 | MP100 | 1.8F
1.0C | Full Range w/
Optional Probe:
-300 to +2000°F | 是 |
SM325 | MP100 | 1.8F
1.0C | Full Range w/
Optional Probe:
-300 to +2000°F | 是(2) |
SM420 | MP100 | 0.5F
0.3C | -50 to 350F
-45 to 176C | 是 |
SM720 | 以太网 | 1.8F
1.0C | -300 to 2000F
-184 to 1093C | 是 |
SM725 | 以太网 | 1.8F
1.0C | -300 to 2000F
-184 to 1093C | 是(2) |
DICKSON VFC320/325疫苗监测温度数据记录仪
型号 | 温度范围 | 温度精度 | 远程探头 | 带数显 | 报警 | 带电池 |
VFC320 | -20 to 158F (-29 to 70C) | +/- 1.8F from -4 to 158F | 是 | 是 | 是 | 是 |
VFC325 | -20 to 158F (-29 to 70C) | +/- 1.8 F from -4 to 158 F | 是(2) | 是 | 是 | 是 |
DICKSON FH520/525/535触摸屏温湿度数据记录仪(FH320/325已停产)
型号 | 温度范围 | 温度精度 | 湿度范围 | 湿度精度 | 远程探头 | 带数显 | 报警 |
FH520 | 0 to 122 F | +/- 0.8 F from 20 to 122 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH | | 是 | 是 |
FH525 | -40 to 185 F | +/- 0.8 F from 20 to 122 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH
+/- 3 % RH from 60 to 95 % RH | 是 | 是 | 是 |
FH535 | -40 to 185 F | +/- 0.8 F from 20 to 122 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH
+/- 3 % RH from 60 to 95 % RH | 是 | 是 | 是 |
DICKSON FT500/525/520/530触摸屏温度数据记录仪(FT300/325/420已停产)
型号 | 温度范围 | 温度精度 | 远程探头 | 带数显 | 报警 |
FH500 | 0 to 122F (-18 to 50C) | +/- 1.2F from 0 to 122F | | 是 | 是 |
FH525 | -40 to 300F (-40 to 149C) | +/- 0.8F from -20 to 176F 1.2F | 是 | 是 | 是 |
FH520 | -300 to 2000F (-184 to 1093C) | +/- 1.8F from -300 to 500F | 是 | 是 | 是 |
FH530 | -300 to 2000F (-184 to 1093C) | +/- 1.8F from -300 to 500F | 是 | 是 | 是 |
DICKSON TP425/325经济型温湿度数据记录仪(TP325已停产)
型号 | 温度范围 | 温度精度 | 湿度范围 | 湿度精度 | 远程探头 | 带数显 | 带电池 |
TP425 | -4 to 158 F | +/- 0.8 F from 20 to 120 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH
+/- 3 % RH from 60 to 95 % RH | 是 | 是 | 是 |
DICKSON TP125经济型温湿度数据记录仪
型号 | 温度范围 | 温度精度 | 湿度范围 | 湿度精度 | 报警功能 |
TP125 | -10 to 176F (-23 to 80C) | +/- 0.8F from 20 to 120F | 0-95% RH non-condensing | +/- 2% RH from 0 to 60% RH +/- 3% RH from 60 to 95% RH | 是 |
DICKSON SP125经济型温度数据记录仪
型号 | 温度范围 | 温度精度 |
SP125 | -10 to 176F (-23 to 80C) | +/- 1.2F from -10 to 176F |
DICKSON TK550/250硬币大小温湿度数据记录仪(TK180/500已停产)
型号 | 温度范围 | 温度精度 | 湿度范围 | 湿度精度 | 数量 |
TK550 | -4 to 158F (-20 to 70C) | +/- 1.8F from -4 to 158F | 0-95% RH non-condensing | +/- 2% RH from 0 to 60% RH (+/- 3% RH from 60 to 95% RH) | 12个/套 |
TK250 | -4 to 158F (-20 to 70C) | +/- 1.8F from -4 to 158F | 0-95% RH non-condensing | +/- 2% RH from 0 to 60% RH (+/- 3% RH from 60 to 95% RH) | 6个/套 |
DICKSON SK550/250硬币大小温度数据记录仪(SK180/500已停产)
型号 | 温度范围 | 温度精度 | 数量 |
SK550 | -4 to 158F (-20 to 70C) | +/- 1.8F from -4 to 158F | 12个/套 |
SK250 | -4 to 158F (-20 to 70C) | +/- 1.8F from -4 to 158F | 6个/套 |
DICKSON WH220/225/245无线温湿度数据记录仪
无线温湿度数据记录仪
型号 | 温度范围 | 温度精度 | 湿度范围 | 湿度精度 | 远程探头 | 带数显 | 报警 |
WH220 | -22 to 122 F | +/- 0.8 F from 20 to 122 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH
+/- 3 % RH from 60 to 95 % RH | | | |
WH225 | -22 to 122 F | +/- 0.8 F from 20 to 122 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH
+/- 3 % RH from 60 to 95 % RH | | 是 | |
WH245 | -40 to 185 F | +/- 0.8 F from 20 to 122 F | 0-95% RH non-condensing | +/- 2 % RH from 0 to 60 % RH
+/- 3 % RH from 60 to 95 % RH | 是 | 是 | 是 |
可另配接收器及软件接收或通过电邮或文件形式发送数据
DICKSON WT200/220/240无线温度数据记录仪
无线温度图表记录仪
型号 | 温度范围 | 温度精度 | 远程探头 | 带数显 | 报警 |
WT200 | -22 to 122 F | +/- 0.8 F from 20 to 122 F | | | |
WH220 | -22 to 122 F | +/- 0.8 F from 20 to 122 F | | 是 | |
WH240 | -300 to 2000 F
-300 to 500 F | +/- 0.8 F from 20 to 122 F
+/- 1.8 F from -22 to 122 F | 是 | 是 | 是 |
可另配接收器及软件接收或通过电邮或文件形式发送数据
DICKSON HT200/220/225耐高温防水温度数据记录仪
型号 | 温度范围 | 温度精度 | 远程探头 | 电池 |
HT200 | -40 to 257F (-40 to 125C) | +/- 1.8F from -40 to 257F | | 是 |
HT220 | -40 to 257F (-40 to 125C) | +/- 1.8F from -40 to 257F | 是 | 是 |
HT225 | -40 to 257F (-40 to 125C) | +/- 1.8F from -40 to 257F | 是 | 是 |